Vista Ridge 1R-8 D-LR060103SAM ENGINEERING & TESTING, L.P.
Serving The GeD-Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972} 790-1910 · FAX: (972) 790-0967
CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT
CLIENT: JBP, LP STANDARD 6" X 12"
5301 Village Creek Driv~ Suite A AREA 28.27 SQ. IN.
Piano,
REPORT DATE: 1/3/06
~JECT: The PI~ Infrastructure
H ~d~y 121 & Ridgemont ,~/' 1 f! SAMPLE DATE: 12/2/05
............
Lew sv le & Coppell, TX
' PROJECT NO.: 308TXIK8
ATTN: Neal Heckel ~ V/
J ~ / REPORT NO.: 37
SE&T TECHNICIAN: Jude Brignac
LOCATION OF PLACEMENT: Eastbound Decel. Lane (~ Highland & Plaza Blvd. PAGE 1 OF 1
Time Arrived: ....... 10:55 AM Concrete Supplier: Beall Concrete
Time Left: 12:00 PM Ticket #: 89050292
Slump (Inches): 4.25 Truck #: 108
Concrete Temperature (F): 60 Time Batched: 11:09 AM
% Air Content: N/A Time Sampled: 11:35 AM
Total No. of Test Cylinders Made: 4 Product Code: 340L1504
Total Cubic Yards Placed: 20 Cement: NIA
Added Water: N/A Fly Ash: N/A
Weather Conditions: Partly Cloudy & Cool Coarse Aggregate: N/A
Air Temperature (F): 52 IWater: N/A
t: N/A
' lA 7 12/9/05 141 80,000 282
lB ~ 14 112/18/05I 144 I 97,000 I 3430 I Sin~leShear I 4000/28
~30/05I 143I 139,000 I 4916 J Single Shear I 4000/28
~30/05 I 143 I 144,000 I 5092 I Single Shear I 4000/28
~t Me hodt ~Cylinder Made B~r~ Cylinders Tested By:
~ C-143 IASTM C-39 & 231 I SE&T I SE&T
Remarks: Tested concrete meets/exceeds required strength,
VeryT ruly Yours,~
Sadik (SAM) AI-Musawe, MSc., Ph.D., P.E.
Civil & Environmental Engineer
Texas Registration Number: 61893
This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent.
This report only applies to the samples tested and does not necessarily represent identical or similar samples.
G:12005130BtxikSICpistrlCpistr37/eE