ST9302-LR 991022 (6) REPORT OF CONCRETE
COMPRESSION TEST
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR: CITY OF COPPELL DATE OF ~SSUE: 10/22/99
COPPELL, TEXAS
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93-02 OUR REPORT NO.: 98881-99
COPPELL, TEXAS
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 51 +00
DATE PLACED 10/22/99 PLANT N/A
TIME / 15:15 DELIVER TICKET NO. 20289
SLUMP (ASTM C-143) / 3 MIX PROPORTIONS (SSD)
AIR CONTENT (ASTM C-231 [] OR C-173[~ 4 CEMENT N/A
AIR TEMPERATURE 91 WATER N/A
CONCRETE TEMPERATURE 89 FINE AGGREGATE N/A
DATE RECENED 'J 0/25/99 COARSE AGGREGATE N/A
FIELD DATA SUBMITTED BY KALU ,,. ADMIXTURE N/A
MIX DATA SUBMITTED BY TXJ
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-~17 [] OR C-1231
COMPRESSION TEST RESULTS L_-.-.-~ Cylinders made by ALPHA
(NOMINAL CYLINOER SIZE $" X 12") representative.
(ASTM C-39) [] Cylinders made by Archilecl's
or Contractor's representative.
LAB ,~'PE DATE rI AGE TOTAL AREA COMPRESSIVE D~.~indefs picked ,p by ALPHA
NO. CURING TESTED DAYS LOAD STRENGTH, PSI laboratow.
90 LAB 10/29/99 7 i 01,969 28.27 3,610 [] Cylinders delivered to ALPHA
91 LAB 11/19/99 28 122,189 28.27 4,320 // laboratory.
92 LAB 11/19/99 28 123,096 28.27 4,350~Compression test results comply with
93 LAB 10/26/99 4 70,553 28.27 2,500 applicable specifications.
[] Compression tesl results do not comply
with applicable specifications.
Specifications 28 3,OO0 //' 'R~
REMARKS:
Geotechnical Engineering · Construction Materials Te~ng · Environmental Engineering · Consulting