Loading...
Coppell Trade-LR060118CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0161 Service Date: November 22, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 Report Date:January 18, 2006 Project: reffacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:00am Supplier: TXI Truck No: 805 Mix I.D. No.: 8602 Plant: 141 Ticket No: 160333 Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 4.2 Concrete Temperature,° F: 65 Ambient Temperature, o F: 46 Plastic Unit Weight, pcf: Sample Information Sample Time: 9:11am Date Cast: November 22, 2005 Technician: Daniel J. Dregos Weather Conditions: Cool and sunny Accumulative Yards: 30 Placement Method: Direct Discharge Sample Locations: Sidewalk, W side at F/24 Placement Location: Building C, W side Entrances at Column Line F/13, F/19 and F/24 Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM Cl 064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/29/2005 7 114,300 4,040 1 2 6.00 28.27 12/20/2005 28 156,480 5,530 1 3 6.00 28.27 12/20/2005 28 150,420 5,320 Average 5,430 1 4 6.00 28.27 01/17/2006 56 166,200 5,880 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Drogos (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) TechniStructures (1) McFadden & Miller Reviewed by: (1) City of Coppell TX (1) Macatee Engineering Inc (1) City of Coppell TX The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0181 Service Date: January 10, 2006 Client: Coppell Trade Center LP Attn: Bennet Rafliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date:January 18, 2006 Project: '1 rerracon 8901 Carpenter Fnvy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:25am Plant: 141 Supplier: TXI Truck No: 715 Ticket No: 184161 Mix I.D. No.: 564 Water Added Onsite Before Test: 5Gallons Water Added Onsite After Test: 0Gallons Field Test Data Test Result Slump, inches: 4.50 Air Content, %: 5.0 Concrete Temperature, o F: 56 Ambient Temperature, o F: 33 Plastic Unit Weight, pcf: 143 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 Sample Information sample Time: 7:40am Date Cast: January 10, 2006 Technician: Polikarp J. Labecki Weather Conditions: Partly sunny Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Outer Sections Placement Location: Pavement, W Approach Drive Specification Test Method 3-5 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/13/2006 3 87,860 3,110 1 2 6.00 28.27 01/17/2006 7 119,450 4,220 1 3 6.00 28.27 01/17/2006 7 126,340 4,470 Average 4,350 1 4 02/07/2006 28 1 5 02/07/2006 28 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2