Loading...
Coppell Trade-LR060116FIELD DENSITY TESTING Report Number: 94051190.0179 Service Date: January 9, 2006 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 Report Date: January 16, 2006 Project: 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Dry Unit Water Minimum Dry Material Laboratory Content Weight Content Unit Weight No. Test Method Description and Classification (%) (pcf) (%) (% compaction) 1. 510810065 ASTM D 698 Crushed limestone flexible base 8.4 124.8 -2/+2 95 2. 510810001 ASTM D 698 Light brown & brown clay w/sand & gravel 19.8 101.6 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (%compaction) Spread Footings 448 Retest of Test #447, dated 1/6/06 1 6 8.9 122.3 98 Drive Approach 449 SW of job site Final 2 6 20.4 100.9 99 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Armaodo Rendon Field Results Reported To: Superintendent Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) Cily of Coppell TX (1) City of Coppell TX (1) Merdman Assoc loc (1) McFadden & Miller (1) Macatee Engineering loc Robert D. Ray, Senior Project Manger The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0176 Service Date: January 6, 2006 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Spdngs Rd Ste 300 Addison TX 75001 Report Date:January 16, 2006 Project: rerfacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Coppell Trade Center- Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 6:33am Plant: 31 Supplier: TXI Truck No: 136 Mix I.D. No.: 9506 WaterAdded Onsite Before Test: 10Gallons Water Added Onsite After Test: 0Gallons Field Test Data Test Result Slump, inches: 4.00 Air Content, %: 1.3 Concrete Temperature,° F: 57 Ambient Temperature, o F: 40 Plastic Unit Weight, pcf: 146.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Ticket No: 182053 Sample Information sample Time: 7:20am Date Cast: January 6, 2008 Technician: Barry Cuble Weather Conditions: Clear and cool Accumulative Yards: 10/15 Placement Method: Direct Discharge Sample Locations: 5-25' W of building Placement Location: Retaining Wall Spread Footing Specification Test Method 3-5 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/13/2006 7 109,370 3,870 01/13/2006 7 111,700 3,950 Average 3,910 02103/2006 28 02/03/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples, Technician: Barry Cuble Report Distribution: (1) Co.ell Trade Center LP (1) Merdrnan Assoc Inc (1) TechnlStructures (1) McFadden & Miller Reviewed by: (1) City of Cop. Il TX (1) Macatee Engi.eerlng .nc (1) City of Coppell TX Senior Project Manager~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein ara only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I o~ ~.o~.F~.. ~.~