Loading...
Coppell Trade-LR060113CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0169 Service Date: December 15, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: January 13, 2006 Project: 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Coppell Trade Center- BId9 C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 7:00am Supplier: TXI Truck No: 67 Mix I.D. No.: B8274 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 141 Ticket No: 171311 0Gallons 0 Gallons Sample Information Sample Time: 8:30am Date Cast: December 15, 2005 Technician: Kudret Aksu Weather Conditions: Clear Accumulative Yards: 7/15 Placement Method: Direct Discharge Sample Locations: E half portion covered area Placement Location: Pavement, approach, E covered approach on Sandy Lake Field Test Data Test Result Slump, inches: 4.50 Air Content, %: 3.5 Concrete Temper'ature,° F: 54 Ambient Temperature, o F: 33 Plastic Unit Weight, pcf: 148.0 Laboratory Test Data set specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/22/2005 7 135,280 4,780 1 2/22/2005 7 133,280 4,710 Average 4,750 01/12/2006 28 159,870 5,650 01/12/2006 28 170,220 6,020 Average 5,840 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu Report Distribution: ~ / J (1) TechniStmctures (1) ~Fadden & Miller ~evleweo Dy. ~/~ ~ ~,/ (1) Ci~ of Cop~ll TX (1) Macat~ Engineering Inc ~ R~A D. Ray, S.E.T.~ (1) C~ of Coppell TX Senior Proj~t M~. The t~ ~re ~ormed in general ac~rdance ~th applicable ASTM, AASHTO, or DOT test meth~s. This repod is ~clusively for the u~ ~e client indicat~ a~ve and shall n~ ~ repr~uc~ ~ce~ in full wEhout the ~en ~nsent of our core.ny. Te~ results tmnsm~ herein are only applicable to the actual samples tested at the I~ation(s) referenced and are n~ n~es~rily indicative of the prope~ies of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0167 Service Date: December 15, 2005 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: January 13, 2006 Project: ll'erracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 _Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:24am Plant: 143 Supplier: TXI Truck No: 108 Ticket No: 171263 Mix I.D. No.: 8203 Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 4.75 Air Content, %: 3,9 Concrete Temperature, O F: 47 Ambient Temperature, o F: 32 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Sam~ Information Sample Time: 7:30am Technician: Kudret Aksu Weather Conditions: Cloudy Accumulative Yards: 7/10 Placement Method: Pump Sample Locations: Same as placement Placement Location: Retaining Wall at NE corner of building Date Cast: December 15, 2005 Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM 01O64 ASTM O1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/22/2005 7 88,090 3,120 12/22/2005 7 88,930 3,140 Average 3,130 01/1 2/2006 28 113,250 4,000 01/1 2/2006 28 114,750 4,060 Average 4,030 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu (1) TechniS ructures (1) McFadden & Miller ~ ,~v,,~ .... ~.../J ~-~-- ,,-. r_ '.r_ ~ _/..~ (1) City of Cop~N~II TX (1) Macatee Engineering Inc Robert DRay, S..~Tj~ (1) City of C~ppelt TX ~enior Project M/q~/~e! . .. The tests were performed in general accordance with appl cab e ASTM, AASHTO, or DOT test methods. This report is exclusively for th~ .es of th~ cl!e. nt halt not be re roduced except in full without the written consent of our company. Test results transmitted herein are only applicable indicated above and s P . -- - -- ar v nd nat va of the Drooert es of other apparent y sim ar or identical to the actual samples tested at the location(s) referenceo ano are not necess..... ............. materials. Page 1 of 1 0,.p~,-~.~KW