Loading...
Amberpoint BP 2R-LR060202WATER INJECTION OBSERVATION 'l ffl!lcon Consultlml Engineers & Scientists 8901 Carpenter Frwy., Suite #100 Darlas, Texas 75247 (214) 630-1010 Date of Service: Client No.: Client: Location: 02/02/06 50854 Transwestem Commercial Services 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 Buildings #5 and #6, see attached sketch Report No.: Project No.: Project: General Contractor: Injector: 94051418.0152 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Rogers-O'Brien Jowell Procedure: On this date, a Terracon technician observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 8th & 6th No. of Probes: 4 Probe Length: 9 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 7 feet. X Spacing of injection was 5 feet maximum. X Injection to refusal at each location. X Comments: Building #5 - 8th pass Building #6 - 6th pass Field Results Report To: Technician: B. Thomas Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell TX (1) City of Coppell TX 99as (1) Rogers O'Brien Construction Co (1) O'Brien & Assoc (1) TechniStructures H~Abusaad, P.E. Senior Project Manager This repot[ is exclusively for the use of the client indicated above and shall not be reproduced in full without wdtten approval of Terracon WATER INJECTION OBSERVATION SKETCH lrerracon Date of Service: Client No,: Client: 02/02/06 50854 Transwestem Commercial Services 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 Report No.: Project No.: Project: 94051418.0152 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Building #5 Building #6 Not to Scale S W CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0118 Service Date: January 25, 2006 'lrl ffiilcon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: February 02, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 2:31pm Plant: 6 Supplier: Potter Concrete Truck No: 808 Ticket No: 6269730 Mix I.D. No.: 1261 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 0.4 Concrete Temperature, o F: 75 Ambient Temperature, o F: 68 Plastic Unit Weight, pcf: Laborator~ Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 Sample Information Date Cast: January 25, 2006 Technician: J. Johnson Weather Conditions~'adly cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Sta. 19+26.35, Line A Placement Location: Inlet Specification Test Method Time:3:32pm 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 02/01/2006 7 103,930 3,680 1 2 02/22/2006 28 1 3 02/22/2006 28 4 03/22/2006 56 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Drogos Report Distribution: ~ (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) City of Coppell TX (1) TechniStructures Reviewed by: (1) City of Coppell TX Hussein H. Abusaad, P.E. (1) Rogers O'Bden Construction Co Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 D~.,cs~o~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0115 Service Date: January 25, 2006 "lr fr con 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: February 02, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 .505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 8:35am Plant: 2 Supplier: Potter Concrete Truck No: 109 Ticket No: 102356 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 1.1 Concrete Temperature,o F: 63 Ambient Temperature, o F: 67 Plastic Unit Weight, pcf: 150.0 Laboratory Test Data Sample Information Date Cast: January 25, 2006 Technician: Daniel J. Drogos Weather ConditionsSunny and warm Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: Pier G/21 Placement Location: Piers Specification 5-7 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 02/01/2006 Time:8:55am Test Method ASTM C143 ASTM C231 ASTM Cl 064 ASTM Cl 064 ASTM Cl 38 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 88,860 3,140 1 2 02/22/2006 28 1 3 02/22/2006 28 1 4 03/22/2006 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 o, ACS~O$ CO'Ire Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0115 Service Date: January 25, 2006 'lrl ffacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: February 02, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:30am Plant: 2 Supplier: Potter Concrete Truck No: 126 Ticket No: 102365 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 5.75 Air Content, %: 1.1 Concrete Temperature,o F: 70 Ambient Temperature, o F: 72 Plastic Unit Weight, pcf: 149.6 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) Sample Information Date Cast: January 25, 2006 Technician: Daniel J. Drogos Weather ConditionsSunny Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: Pier J/18 Placement Location: Piers Specification 5-7 Date Tested Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Time:12:31pm 2 1 6.00 28.27 02/01/2006 7 91,780 3,250 2 2 02/22/2006 28 2 3 02/22/2006 28 2 4 03/22/2006 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Drogos Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & As$oc /~-~::~ J (1) City of Coppell TX (1) TechniStructures Reviewed by: (1) City of Coppell TX H.~ssein H. Abusaad, P.E. (1) Rogers O'Brien Construction Co Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actua~ samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. REPORT OF REINFORCING STEEL OBSERVATION !~[~r~.~.E~l~..~n~ 8901 Carpenter Frwy, Suil¢ #l a0 Date of Service: 02/02/06 Report No.: Client No.: 50854 Project No.: Client: Transwestern Commercial Services Project: 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 Drawings Utilized: 94051418.0148 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA Civil Sheet 2050 of Specification Book, dated November 2003 Locations/Items Observed: Pavement at S side of Building #4, See attachments 1 & 2 for location of areas observed. Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT iNCORRECT PLacing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size j~ Proper Bar Placement X Slirrup Spacing & Typo Sar Grade X Propedy Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debds Rerc~ved X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: Any discrepancies found were corrected at the time of this observation unless otherwise noted. Field Results Report To: Technician: M. Garcia Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell TX (1) City of Coppell TX 309acs (1) Rogers O'Brien Construction Co (1) O'Brien & Assoc {1) TechniStructures Hussein H. Abusaad, P.E. Senior Project Manager This report is exclusively for the use of the client indicated above and shall not be reproduced without written approval of Terracon