Coppell Trade-LR060201CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0194
Service Date: January 24, 2006
Client:
Coppell Trade Center LP
Attn: Bennet Ratliff
5055 Keller Springs Rd Ste 300
Addison TX 75001
'lrerfacan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: February 01, 2006
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project No.: 94051190
Material Information
Specified Strength: 4000 psi ~ 28 Days
Batch Time: 6:49am Plant: 141
Supplier: TXI
Truck No: 101 Ticket No: 192899
Mix I.D. No.: B8276
Field Test Data
Test
Result
Slump, inches: 5.00
Air Content, %: 5.0
Concrete Temperature, o F: 54
Ambient Temperature, o F: 32
Plastic Unit Weight, pcf: 143.0
Laboratory Test Data
Set Specimen Diameter
No.
ID (inches)~(sq. inches)
1 6.00 28.27
Sample Information
Date Cast: January 24, 2006
Technician: Po[ikarp J. Labecki
Weather Conditions~lear sky
Accumulative Yards:8/16
Placement Method: Direct Discharge
Sample Locations: SW corner
Placement Location: Pavement, W Exit Approach Drive
Time:7:30am
Specification Test Method
3-5 ASTM C143
3-7 ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Age at Maximum Compressive
Date Test Load Stren~.th
Tested (days) (lbs)
01/27/2006 3 101,620 3,590
1 2 6.00 28.27 01/31/2006 7 98,740 3,490
1 3 6.00 28.27 01/31/2006 7 101,440 3,590
Average 3,540
1 4 02/21/2006 28
1 5 02/21/2006 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Polikarp J. Labecki
Report Distribution:
(1) Coppell Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppell TX
(1) Merriman Assoc Inc
(1) McFadden & Miller
(1) Macatee Engineering Inc
Reviewed by: sR_~
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wriffen consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
Page 1 of I