Loading...
Coppell Trade-LR060127 FIELD DENSITY TESTING Report Number: 94051190.0190 Service Date: January 17, 2006 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: Project: January 27, 2006 Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Description and Classification Dark reddish brown sandy clay Dark reddish brown sandy clay Project No.: 94051190 Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight ('!o) (pet) 15.2 106.2 15.2 106.2 Proiect Reauirements Material Information Material No. Laboratory Test Method Water Content ('!o) >/= +2 -1/+3 Minimum Dry Unit Weight (% compaction) 1 510810002 ASTM D 698 2 510810002 ASTM D 698 Field Test Data Test No. 92 95 Probe Water Dry Unit Dry Unit Lift/ Mat. Depth Content Weight Weight Elev No. (inches) ('!o) (pet) (% compaction) 1'BG 2 6 15.4 105.2 99 3' BG 2 6 14.9 105.6 99 3' BG 1 6 18.9 100.7 95 3' BG 1 6 18.5 101.3 95 Test Location 452 453 454 455 Slab Leaveout 20' N & 2' W of SW corner of building 40' N & 2' W of SW corner of building 20' N & 2' E of SW corner 30' N & 2' E of SW corner Datum: BG = below grade Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test MethodASTM D2922, ASTM D3017 Technician: Armando Rendon Field Results Reported To: Superintendent ~ Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Report Distribution: (1) Coppell Trade Center LP (1) TechniStruclures (1) CilyofCoppeJl TX (1) CilyofCoppell TX (1) Merriman Assoc lnc (1) McFadden & Miller (1) Macalee Engineering Inc Reviewed by: Page 1 of 1 07-PORiR07-FuturOKey CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0192 Service Date: January 19, 2006 lrerracon 8901 Carpenter Frwy, Ste #1 00 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: January 27, 2006 Project: Coppell Trade Center - Bldg C NWC Sandy Lake/Freeport Pkwy Coppell, TX 10Gallons o Gallons Project No.: 94051190 Sample Information Date Cast: January 19, 2006 Time:8:00am Technician: Kudret Aksu Weather ConditionsCloudy Accumulative Yards: 7 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Retaining Wall at SW corner of building Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:30am Supplier: TXI Truck No: 921 Mix I.D. No.: 8206 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, 0 F: Ambient Temperature, 0 F: Plastic Unit Weight, pcf: Laboratory Test Data Plant: 141 Ticket No: 190077 Result 5.00 4.6 67 54 144.2 Spec ifi cati 0 n 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 1 5 Date Tested 01/23/2006 Age at Test (days) 4 Maximum Compressive Load Strength (Ibs) (psi) 80,240 2,840 01/26/2006 01/26/2006 7 105,790 7 105,710 Average 28 28 3,740 3,740 3,740 02/16/2006 02/16/2006 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu Report Distribution: (1) Coppell Trade Center LP (1) TechniSlructures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Inc (1) McFadden & Miller (1) Macalee Engineering Inc Reviewed by: Robert D. Ray, S. Senior Project Mager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01_POOillOI.Fu!ur.~.y