Coppell Trade-LR060202CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0173 Service Date: January 4, 2006 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: February 02, 2006 Project: Coppell Trade Center- BIdg C NWC Sandy Lake/Freeport Pkwy Coppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:51am Supplier: TXI Truck No: 837 Mix i.D. No.: 8206 Plant: 141 Ticket No: 179970 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.7 Concrete Temperature,o F: 73 Ambient Temperature, o F: 57 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) Sample Information Date Cast: January 4, 2006 Technician: Daniel J. Drogos Weather ConditionsPartly cloudy, cool Time:7:30am Placement Method: Direct Discharge Sample Locations: Adjacent to Grid 1.75, 50' S of building Placement Location: Pavement, approximately 120' S of Grid A & Grid 1.5-2.0 Specification Date Tested Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 1 1 6.00 28.27 01/11/2006 7 125,270 4,430 1 2 6.00 28.27 02/01/2006 28 158,220 5,600 1 3 6.00 28.27 02/01/2006 28 158,350 5,600 Average 5,600 1 4 03/01/2006 56 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Drogos Report Distribution: (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) TechniStructures (1) McFadden & Miller Reviewed by: (1) Cib/of Coppell TX (1) Macatee Engineering Inc Robert (1) City of Coppell TX Senior Project Man~ The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repeal is exclusively for the use,,e~e client indicated above and shall not be reproduced except in fulJ without the written consent of our company. Test results transmitted herein are on~"'applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.