Loading...
Amberpoint BP 2R-LR060215WATER INJECTION OBSERVATION 'lrerracon Consulting EngJneers & Scientists 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Date of Service: Client No,: Client: Location: 02/I 5/06 50854 Transwestem Commercial Services 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 Report No.: Project No.: Project: 94051418.0206 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Building#6 General Contractor: Rogers-O'Brien Injector: Jowell Procedure: On this date, a Terracon technician observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 0 No. of Probes: 0 Probe Length: 0 OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 10 feet. X Spacing of injection was 5 feet maximum. X Injection to refusal at each location. X Comments: Injector Jowel did not show up for injection. Contractor Rogers O'Brien asked me to stay until 2:30 or 3:00 o'clock if they did not show for me to leave. Field Results Report To: Technician: T. Smith Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell TX (1) City of Coppell TX 99 (1) Rogers O'Brien Construction Co (1) O'Brien & Assoc (1) TechniStructures Hussein H. Abusaad, P.E. Sezfior Project Manager This repod is exclusively for the use of the client indicated above and shall not be reproduced in full without wrilten approval of Terracon~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0174 Service Date: February 7, 2006 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 'lrerfacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: February 15, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3600 psi ~ 28 Days Batch Time: 5:49am Plant: On-site Supplier: Potter Concrete Truck No: 106 Ticket No: 102592 Mix I.D. No.: 7752 Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.9 Concrete Temperature,o F: 73 Ambient Temperature, o F: 42 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Sample Information Date Cast: February 7, 2006 Technician: Ira S. Haynes Weather Conditions~lear Accumulative Yards: 110/330 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Pavement, Parking Lot Time:6:15am Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 02/14/2006 7 125,900 4,450 02/14/2006 7 127,580 4,510 Average 4,480 03/07/2006 28 03/07/2006 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the p[acement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 0~ ~0, ~o K~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0174 Service Date: February 7, 2006 refracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: February 15, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3600 psi ~ 28 Days Batch Time: 6:42am Plant: On-site Supplier: Potter Concrete Truck No: 122 Ticket No: 102603 Mix I.D. No.: 7752 WaterAdded Onsite Before Test: 0Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 5.1 Concrete Temperature,o F: 73 Ambient Temperature, o F: 43 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 2 4 Sample Information Date Cast: February 7, 2006 Technician: Ira S. Haynes Weather ConditionsZ~lear Accumulative Yards:220/330 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Pavement, Parking Lot Time:7:15am Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 02/14/2006 7 110,270 3,900 02/14/2006 7 112,870 3,990 Average 3,950 03/07/2006 28 03/07/2008 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of oar company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical rnaterials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0085 Service Date: January 17, 2006 'lrerracon 8901 Carpenter Fr~, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date:February 15, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Ma terial In formation Specified Strength: 4200 psi @ 28 Days Batch Time: 3:36pm Plant: 7 Supplier: Latfimore Materials Co. Truck No: 1098 Ticket No: 7160296 Mix I.D. No.: 1851 Water Added Onsite Before Test: 0Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Sample Information Date Cast: January I7, 2006 Time:3:46pm Technician: Burl E. Thomas Weather ConditionsZ;lear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: A/2, A/3, A/4 Placement Location: Inlets at A/2 at Sra. 0+29.76, A/3 at Sta. 30+45, A/4 at Sta. 0+31.25 Specification Test Method Result Slump, inches: 4.00 Air Content, %: 3.0 Concrete Temperature,o F: 65 Ambient Temperature, o F: 55 Plastic Unit Weight, pcf: 148.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load String, th No. ID (inches) (sq. inches) Tested (days) (lbs) ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 1 1 6.00 28.27 01/24/2006 7 133,170 4,710 1 2 6.00 28.27 02/14/2006 28 170,670 6,040 1 3 6.00 28.27 02/14/2006 28 170,020 6,010 Average 6,030 Comments: NOTE: COG Class A(?) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Burl E. Thomas Repod Distribution: Transwestern Commercial Services (1) O'Brien & Assoc ~ (1)(1) City of Coppell TX (1) Techn~Structures Reviewed by: ...~.,, ~' (1) City of Coppell TX ~. Abusaad, P,E. (1) eogers O'Srien Construction Co Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94051418.0174 Service Date: February 7, 2006 'll'erracon 8901 Carpenter Frwy, Sfe #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: February 15, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3600 psi ~ 28 Days Batch Time: 7:32am Plant: On-site Supplier: Potter Concrete Truck No: 106 Ticket No: 102611 Mix I.D. No.: 7752 Water Added Onsite Before Test: 5Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 5.2 Concrete Temperature,o F: 71 Ambient Temperature, o F: 43 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Date Cast: February 7, 2006 Technician: Ira S. Haynes Weather Conditions:Clear Accumulative Yards:300/330 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Parking Lot Time: 8:04am Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 02/14/2006 7 108,870 3,850 3 2 6.00 28.27 02/14/2006 7 104,200 3,680 Average 3,770 3 3 03/07/2006 28 3 4 03/07/2006 28 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) Comments: Not tested for plastic unit weight Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. Technician: Ira S. Haynes Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Asso¢ (1) City of Coppell TX (1) TechniStructures Reviewed by: (1) City of Coppell TX H~. Abusaad, P.E. (1) Rogers O'Brien Construction Co Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 3 of 3 CONCRETE COMPRESSIVE STRENGTH TEST SKETCH " fflilcon Date of Service: 02/07/06 Report No.: Client No.: 50854 Project No.: Client: Transwestem Commercial Services Project: 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 94051418.0174 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Sample #2 ] pie #3 ] Not to Scale South Side, West of Fire Lane