Coppell Trade-LR060222CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051190.0194 Service Date: January 24, 2006 '] reffi!lcon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Bennet Ratliff 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: Project: ~ppell I raae center Ooppell, TX Project No.: 94051190 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:49am Supplier: TXI Truck No: 101 Mix I.D. No.: B6276 Plant: 141 Ticket No: 192899 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 5.0 Concrete Temperature, o F: 54 Ambient Temperature, o F: 32 Plastic Unit Weight, pcf: 143.0 Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 Sample Information Date Cast: January 24, 2006 Technician: Polikarp J. Labecki Weather Conditions~lear sky Accumulative Yards: 8/16 Placement Method: Direct Discharge Sample Locations: SW corner Placement Location: Pavement, W Exit Approach Drive Specification 3-5 3-7 Time:7:30am Date Tested 01/27/2006 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 3 101,620 3,590 1 2 6.00 28.27 01/31/2006 7 98,740 3,490 1 3 6.00 28.27 01/31/2006 7 101,440 3,590 Average 3,540 1 4 6.00 28.27 02/21/2006 28 128,680 4,550 1 5 6.00 28.27 02/21/2006 28 123,530 4,370 Average 4,460 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Polikarp J. Labecki Report Distribution: (1) Coppell Trade Cenler LP (1) TechniSlructures (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc Inc (1) McFadden & Miller (1) Macatee Engineerir~g fnc Reviewed by: ~ Senior Project ~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.