Amberpoint BP 2R-LR060222WATER INJECTION OBSERVATION
"lrerfacon
Da[las, Texas 75247
(214) 630-1010
Date of Service:
Client No.:
Client:
Location:
02/22/06
50854
Transwestem Commercial Services
5001 Spring Valley Rd Ste 600 W
Dallas, TX 75244
Building #6, see attached sketch
Report No.:
Project No.:
Project:
General Contractor:
Injector:
94051418.0225
94051418
AmberPoint Business Park
Buildings 4, 5 and 6
505 South Royal Lane
Coppell, TX
Rogers-O'Brien
Jowell
Procedure:
On this date, a Terracon technician observed the injection of water at this site. During the
injection process, the following observations were recorded.
Pass No.: 2nd No. of Probes: 4 Probe Length: l0 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
h~jection pressure 50 to 200 psi at manifold. X
h~jection downward in 18 inch intervals. X
Total depth of injection was 7 feet. X
Spacing of injection was 5 feet maximum. X
Injection to refusal at each location. X
Comments:
Field Results Report To:
Technician: J. Johnson
Report Distribution:
(1) Transwestern Commercial Services
(1) City of Coppell TX
(1) City of Coppell TX
(1) Rogers O'Brien Construction Co
(1) O'Brien &Assoc
(1) TechniStructures
Hus,~busaa~, P.E.
Sen[or Project Manager
99pdr This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval of Terracon.
WATER INJECTION OBSERVATION SKETCH
lreffacon
8901 Carpenter Frwy,. Suite
Dallas, Texas 75247
(214} 630-1010
Date of Service: 02/22/06 Report No.:
Client No.: 50854 Project No.:
Client: Transwestem Commercial Services Project:
5001 Spring Valley Rd StP 600 W
Dallas, TX 75244
Not to Scale
94051418.0225
94051418
)dnberPoint Business Park
Buildings 4, 5 and 6
505 South Royal Lane
Coppell, TX
Building #6
27~2~0~ 12/21/06 2/20/06 Pass #1
2/21/06 Pass #2 E~ ]Pass#2
iii!!! i~ii¢!l~ i i
~r~ :;~S ~ 2/21/06 Pass ~1
< 420' >
1
170'
N
S