Loading...
Lost Creek TH-CS060302 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-213-H, Coppell Commons , zoning change request from H (Historic) to PD- 213-H (Planned Development-213-Historic) with a Concept Site Plan to allow the development of 39 townhouse units, recreation, open space and common areas on 5.561 acres of property located along the east side of Coppell Road, approximately 210 feet north of Bethel Road, at the request of Mardy Brown, Dowdey, Anderson & Associates, Inc. STAFF REP.: Gary Sieb PROJECT ID# PD-06-0007 DRC DATE: March 2, 2006 CONTACT: Kenneth M. Griffin, P.E., Dir.of Engineering/Public Works 972/304-3686 COMMENT STATUS: PRELIMINARY FINAL REVISED  AFTER P&Z Preliminary Engineering 1. Show off site development that has taken place adjacent to the property on this sheet. 2. Provide an 8” stub off of the Mobley Way water line that extends to the east property line. The stub should be within an easement and located in “Open Space”. The City will connect the stub to an existing water line on Anderson Avenue. 3. The storm sewer line proposed to empty to the creek should instead be tied to the stub that exists in the variable width utility easement along the east side of the site. 4. The portion of the sanitary sewer line that does not lie within the ROW should be within a minimum 20’ utility easement. 5. Sidewalks that do not lie within the ROW should be located within side walk easements. 6. Provide utility easements in the locations where ROW is reduced due to HOA parking spaces. The easements should cover the difference in standard ROW width. 7. Provide a typical utility and driveway layout for the 26’ lot width. The proposed 26’ may be objectionable if not adequate. 8. Although none is proposed, please note that no construction will be allowed in the 100-year flood plain. 9. Easements meeting the City’s minimum standards will need to be provided during the platting process. 10. The water line shown to connect to the sewer line should be corrected. 11. Is the parallel parking necessary? 12. Consider placing a wheel stops in the parking spaces at the Pommers Ct. cul-de-sac. This may help minimize potential damage to fencing along the abutting property lines. Exhibit “A” 1. 6.0 Road, Alley and Parking Regulations, #5: Minimum parking space width is Nine (9) feet. 2. 6.0 Road, Alley and Parking Regulations, #7: Lay down curbs will only be allowed with the approval of the City Engineer. An additional one foot of street width will be required for each side of the street that the use of lay down curb is allowed. 3. 7.0 Building Regulations, #1: Modify to read “Residential units shall not front on Coppell Road.” Additional comments may be generated upon detailed engineering review. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-213-H~ Coppeil Commons, zoning change request from H (Historic) to PD- 213-H (Planned Development-213-Historic) with a Concept Site Plan to allow the development of 39 townhouse units, recreation, open space and common areas on 5.561 acres of property located along the east side of Coppell Road, approximately 210 feet north of Bethel Road, at the request of Mardy Brown, Dowdey, Anderson & Associates, Inc. STAFF REP.: Gary Sieb PROJECT ID# PD-06-0007 DRC DATE: March 2, 2006 CONTACT: Kenneth M. ~TATUS: ' Worlds 972/304-3686 ,/FINAL RE-Vt-,gE-~ Easements meeting the City's minimum standards will need to be provided during the platting process. Additional comments may be generated upon detailed engineering review.