W Sandy Lk Addn-LR051228CONCRETE CYLINDER TEST REPORT
Sandy Lake 121
944 Sandy Lake Road
Coppell, Texas
REPORTED TO: MC II Development Company, Ltd.
3811 Turtle Creek BIvd, Suite 730
Dallas, Texas 75219
ATTN: Mr. Richard Crow
CONTRACTOR: McFadden & Miller
REPORT NO. 224
REG PROJECT NO. 12130
SAMPLE DATE: 11-30-05
TECHNICIAN: F. Gomez
PAGE: 1 of 1
Location of Sample
Set Number I Location I Quantity Represented
1 Firelane: 10'S, 40'E of NE approach 10/20
Desitin Information
Source of Concrete
TXI
Mix Identification
Specified ¢~tre~gth p.s.i.
8273 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average
No. I ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
6294 12-07-05 7 125290 4430
6294 12-28-05 28 145870 5160
6294 12-28-05 28 146820 5200 5180
6294 Hold H
Cylinder Data
Set Cylinder Time of Concrete Air Ticket
No. I ID Slump Sample Air Temp. Temp. Entrainment Number
1 6294 5.25 8:07AM 39 49 5.3 163811
Mail
Distribution: (1) MC II Development Company, Ltd/
Mr. Richard Crow
(1) Halff Associates/Mr. Dave Littleton
(1) Azimuth Architecture/Mr. John Taylor
(1) McFadden & MilledMr. Jon Jacobson
Submitted by:
REED ENGINEERING GROUP, LTD.
Arthur Etherly, III
Manager, CMT
AE/Inc
2424 STUTZ DR ', SUITE 400 ,, DALLAS, TX 75235 "TEL [214] 3505600 '* F^× [214] 3500019