Loading...
W Sandy Lk Addn-LR051102GEOTECHNICAL AND I~ F:~ r~l U ~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Sandy Lake 121 944 Sandy Lake Road CoppelI, Texas REPORTED TO: MC II Development Company, Ltd. 3811 Turtle Creek Blvd, Suite 730 Dallas, Texas 75219 ATTN: Mr. Richard Crow CONTRACTOR: McFadden & Miller REPORT NO. 171 REG PROJECT NO. 12130 SAMPLE DATE: 10-05-05 TECHNICIAN: D. Gazley PAGE: 1 of 1 Location of Sample Set Number I Location Firelane: 500'N, 170'W of SW building corner Firelane: 240'N, 160'W of SW building corner Design Information Source of Concrete I Mix Identification TXI 8273 Quantity Represented 30/390 160/390 Specified Strength p.s.i. 4000 Test Results Set Cylinder Age @ Total Load No. ID Date Tested Test lbs. 4762 10-12-05 7 104420 4762 11-02-05 28 124900 4762 11-02-05 28 122540 4762 Hold H 2 Compressive Average Strength p.s.i. Strength p.s.i. 3700 4420 4340 4380 4763 10-12-05 7 107230 3790 4763 11-02-05 28 137270 4860 4763 11-02-05 28 135910 4810 4763 Hold H 484O Cylinder Data Set Cylinder No. I ID 1 4762 2 4763 Time of Concrete Slump Sample Air Temp. Temp. 5.00 07:00 am 75 87 5.50 09:40 am 78 90 Air Ticket Entrainment Number 5.10 131072 3.20 131279 Mail Distribution: (1) MC II Development Company, Ltd/ Mr. Richard Crow (1) Halff Associates/Mr. Dave Littleton (1) Azimuth Architecture/Mr. John Taylor (1) McFadden & Miller/Mr. Jon Jacobson Submitted by: REED ENGINEERING GROUP, LTD. Arthur Etherly, III Manager, CMT AE/cdl 2424 STUTZ DR ', SUITE 400 ,, DALLAS, fX 75235 ', TE~ [214] 350 5600" F^X [214] 350 0019