W Sandy Lk Addn-LR051018GEOTECHNICAL AND [~i R r-1 I I p ENVIRONMENTAL CONSULTANTS REPORTED TO: CONCRETE CYLINDER TEST REPORT Sandy Lake 121 944 Sandy Lake Road Coppell, Texas MC II Development Company, Ltd. 3811 Turtle Creek BIvd, Suite 730 Dallas, Texas 75219 ATTN: Mr. Richard Crow REPORT NO. 161 REG PROJECT NO. 12130 SAMPLE DATE: 09-20-05 TECHNICIAN: G. Tsougarakis CONTRACTOR: McFadden & Miller Location of Sample Set Number I Location 1 2 3 Paving: 55'N, 25'E from N.W. building corner Paving: 50'N, 200'E from N.W. building corner Paving: 60'N, 400'E from N.W. building corner Quantity Represented 60/350 170/350 320/350 Design Information Source of Concrete TXI Mix Identification 8273 Specified Strength p.s.i. 4000 Test Results Age @ Total Load Date Tested Test lbs. Set Cylinder No. ID 1 4266 4266 4266 4266 09-27-05 7 129270 10-18-05 28 149560 10-18-05 28 150230 Hold H Compressive Average Strength p.s.i. Strength p.s.i. 4570 5290 5320 5310 2 4267 09-27-05 7 100690 3560 4267 10-18-05 28 121520 4300 4267 10-18-05 28 120180 4250 4267 Hold H 3 4268 09-27-05 7 105150 3720 4268 10-18-05 28 132180 4680 4268 10-18-05 28 137260 4860 4268 Hold H 4300 4770 Cylinder Data Set Cylinder No. 4266 2 4267 3 4268 Time of ID Slump Sample 5.00 7:50AM 6.00 9:30AM 5.00 1:15PM Concrete Air Ticket Air Temp. Temp. Entrainment Number 75 90 4.2 121980 85 90 4.0 122116 95 94 4.5 122323 Mail Distribution: (1) MC II Development Company, Ltd/ Mr. Richard Crow (1) Halff Associates/Mr. Dave Littleton (1) Azimuth Architecture/Mr. John Taylor (1) McFadden & Miller/Mr. Jon Jacobson Submitted by: REED ENGINEERING GROUP, LTD. Arthur Etherly, III Manager, C.M.T. AE/cn 2424STUTZ DR " SUI]E 400 · DALLAS, TX 75235 " TEE [214] 350 5600 · F^X [214] 350 0019