Loading...
W Sandy Lk Addn-LR050817CONCRETE CYLINDER TEST REPORT Sandy Lake 121 944 Sandy Lake Road CoppelI, Texas REPORTED TO: MC II Development Company, Ltd. 3811 Turtle Creek Blvd, Suite 730 Dallas, Texas 75219 ATTN: Mr. Richard Crow REPORT NO. 80 REG PROJECT NO. 12130 SAMPLE DATE: 07-20-05 TECHNICIAN: C. Johnson CONTRACTOR: McFadden & Miller Location of Sample Set Number I Location 1 Parking Lot & Firelane: 15'S, 130'E of SW bldg. corner Quantity Represented 60/130 Desitin Information Source of Concrete I Mix Identification LMC 8273 Specified Strength p.s.i. 4000 Test Results Set Cylinder Age @ Total Load Compressive Average No. I ID Date Tested Test lbs. Stren~lth p.s.i. Stren~lth p.s.i. I 2619 07-27-05 7 129410 4580 2619 08-17-05 28 144880 5130 2619 08-17-05 28 145620 5150 5140 Cylinder Data Set Cylinder Time of Concrete Air Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 1 2619 5.5 7:15AM 70 76 4.6 84897 Mail Distribution: (1) MC II Development Company, Ltd/ Mr. Richard Crow (1) Halff Associates/Mr. Dave Littleton (1) Azimuth Architecture/Mr. John Taylor (1) McFadden & MilledMr. Jon Jacobson Submitted by: REED ENGINEERING GROUP, LTD. Keith Atkins Manager, C.M.T. KEA/Inc 2424 STUTZ DR · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 * F^X [214] 350 0019