W Sandy Lk Addn-LR050817CONCRETE CYLINDER TEST REPORT
Sandy Lake 121
944 Sandy Lake Road
CoppelI, Texas
REPORTED TO: MC II Development Company, Ltd.
3811 Turtle Creek Blvd, Suite 730
Dallas, Texas 75219
ATTN: Mr. Richard Crow
REPORT NO. 80
REG PROJECT NO. 12130
SAMPLE DATE: 07-20-05
TECHNICIAN: C. Johnson
CONTRACTOR: McFadden & Miller
Location of Sample
Set Number I Location
1
Parking Lot & Firelane: 15'S, 130'E of SW bldg. corner
Quantity Represented
60/130
Desitin Information
Source of Concrete I Mix Identification
LMC 8273
Specified Strength p.s.i.
4000
Test Results
Set Cylinder Age @ Total Load Compressive Average
No. I ID Date Tested Test lbs. Stren~lth p.s.i. Stren~lth p.s.i.
I
2619 07-27-05 7 129410 4580
2619 08-17-05 28 144880 5130
2619 08-17-05 28 145620 5150 5140
Cylinder Data
Set Cylinder Time of Concrete Air Ticket
No. ID Slump Sample Air Temp. Temp. Entrainment Number
1 2619 5.5 7:15AM 70 76 4.6 84897
Mail
Distribution: (1) MC II Development Company, Ltd/
Mr. Richard Crow
(1) Halff Associates/Mr. Dave Littleton
(1) Azimuth Architecture/Mr. John Taylor
(1) McFadden & MilledMr. Jon Jacobson
Submitted by:
REED ENGINEERING GROUP, LTD.
Keith Atkins
Manager, C.M.T.
KEA/Inc
2424 STUTZ DR · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 * F^X [214] 350 0019