Loading...
Amberpoint BP 2R-LR060314CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0197 Service Date: February 13, 2006 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: March 14, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 3600 psi ~ 28 Days Batch Time: 3:19pm Supplier: Lattimore Truck No: 1107 Mix I.D. No.: 1851 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 7 Ticket No: 7161182 0 Gallons 0 Gallons Result Slump, inches: 4.50 Air Content, %: 5.2 Concrete Temperaturep F: 61 Ambient Temperature,o F: 61 Plastic Unit Weight, pcf: 147.6 Laboratory Test Data Set Specimen Diameter Ama No. ID (inches) (sq. inches) Sample Information Date Cast: February 13, 2006 Technician: Barry Cuble Weather Conditions: Sunny, mild Accumulative Yards: 10/10 Placement Method: Direct Discharge Sample Locations: See Placement Location Placement Location: 8" Double Check Vault, NE Specification Time: 4:15pm Batch Size (cy): 10.00 3-5 3-6 Date Tested Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 1 1 6.00 28.27 02/20/2006 7 134,810 4,770 1 2 6.00 28.27 02/20/2006 7 133,130 4,710 Average (7 Days) 4,740 1 3 6.00 28.27 03/13/2006 28 157,950 5,590 1 4 6.00 28.27 03/13/2006 28 154,870 5,480 Average (28 Days) 6,540 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Barry Cuble Report Distribution: (1) Transwestem Commercial Services (1) TechniStructures /~/ (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by: (1) City of Coppell TX Hussein H. Abusaed, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.