Amberpoint BP 2R-LR060313'lrerracon WATER INJECTION OBSERVATION .901 CarpenterFrwy.,Suite#100 (214) 630-1010 Date of Service: 03/13/06 Report No.: Client No.: 50854 Project No.: Client: Transwestem Commercial Services Project: 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 94051418.0264 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Location: Building #6, see attached sketch General Contractor: Rogers-O'Brien Injector: Jowell Procedure: On this date, a Terracon technician observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 10th No. of Probes: 4 Probe Length: 10 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 10 feet. X Spacing of injection was 5 feet maximum. X Injection to refusal at each location. X Comments: Field Results Report To: Technician: J. Johnson Report Distribution: (1) Transwestem Commercial Services (1) City of Coppell TX (1) City of Coppell TX 99pdr (1) Rogers O*Brien Construction Co (1) O'Bden & Assoc (1) TechniStructures Hussein H. Abusaad, P.E. Senior Project Manager This report is exclusively for the use of the client indicated above and shall not be reproduced in full without wfiffen approval of Terracon. WATER INJECTION OBSERVATION SKETCH 'lrerfacon 8901 CaPpenter Fn,vy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Date of Service: Client No.: Client: O3/13/06 50854 Transwestem Commercial Services 5001 Spring Valley Rd Ste 600 W Dallas, TX 75244 Report No.: Project No.: Project: 94051418.0264 94051418 AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Not to Scale 170' 315' Building #6 420' N S CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0068 Service Date: January 12, 2006 ' refracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date:March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 4200 psi ~ 28 Days Batch Time: 12:18pm Plant: 1 Supplier: Redi-Mix Concrete Truck No: 247 Ticket No: 160702 Mix I.D. No.: 604 WaterAdded Onsite Before Test: 10Gallons Water Added Onsite After Test: 8 Gallons Sample Information Date Cast: January 12, 2006 Time: 1:22pm Technician: Daniel J. Drogos Weather Conditions: Mostly cloudy, windy Accumulative Yards: 5 Placement Method: Bucket Sample Locations: Manholes Placement Location: Manholes, approximately 500' N of SW corner of job site Field Test Data Test Specification Result Slump, inches: 3.50 Air Content, %: 4.2 Concrete Temperaturep F: 77 Ambient Temperature,o F: 75 Plastic Unit Weight, pcf: 152 Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested I 1 6.00 28.27 01/19/2006 1 2 6.00 28.27 02/09/2006 1 3 6.00 28.27 02/09/2006 1 4 6.00 28.27 03/09/2006 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 111,080 3,930 28 168,580 5,960 28 162,450 5,740 Average (28 Days) 5,850 56 174,100 6,160 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Drogos Report Distribution: (1) Transwestern Commercial Se~ices (1) TechniStructures ,~ ~' (1) Ciiy of Coppell TX (1) Rogers O'Brien Conslruclion Co Reviewed by: (1) City of Coppell TX Hussein H. Abusaad, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 940514t8.0192 Service Date: February 10, 2006 rEff lcon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 4200 psi ~ 28 Days Batch Time: 1:29pm Plant: 7 Supplier: Lattimore Truck No: 947 Ticket No: 7161155 Mix I.D. No.: 1851 Water Added Onsite Before Test: 0Gallons Water Added Onsite After Test: 0 Gallons Sample Information Date Cast: February 10, 2006 Technician: Chris Eubanks Weather Conditions: Sunny, windy Accumulative Yards: 7/7 Placement Method: Bucket Sample Locations: See Placement Location Placement Location: Two Inlets, Line D between Sra. 10+81.52 to Sra. 13+69.65 Time: 2:15pm Batch Size (cy): 7.00 Field Test Data Test Result Slump, inches: 4.25 Air Content, %: 5.1 Concrete Temperaturep F: 65 Ambient Temperature,o F: 46 Plastic Unit Weight, pcf: 145.6 Laboratory Test Data Set specimen Diameter Area No. ID (inches) (sq. inches) Specification 2-4 3-6 Date Tested Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C136 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 1 1 6.00 28.27 02/17/2006 7 128,370 4,540 1 2 6.00 28.27 02/17/2006 7 135,540 4,790 Average (7 Days) 4,670 1 3 6.00 28.27 03/10/2006 28 166,010 5,870 1 4 6.00 28.27 03/10/2006 28 163,350 5,780 Average (28 Days) 5,830 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Chris Eubanks Repod Distribution: (1) Transwestern Commercial Services (1) TechniStructures ~ (1) City of Coppell TX (1) Rogers O'Brien Conslruclion Co Reviewed by: (1) City of Coppell TX ~ Husse[n H. Abusaad, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shalJ not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the Iccation(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0187 Service Date: February 9, 2006 ']reffacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No,: 94051418 Material Information Specified Strength: 4200 psi @ 28 Days Batch Time: 3:52pm Supplier: Lattimore Truck No: 5022 Mix I.D. No.: 1851 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Plant: 3 Ticket No: 3238772 5Gallons 0 Gallons Result Slump, inches: 4.00 Air Content, %: 3.0 Concrete Temperaturep F: 63 Ambient Temperature,o F: 63 Plastic Unit Weight, pcf: 148.0 Laboratorl/ Test Data Set specimen Diameter Area No. ID (inches) (sq. inches) Sample Information Date Cast: February 9, 2006 Time: 4:45pm Technician: Burl E. Thomas Weather Conditions: Clear Accumulative Yards: 5 Placement Method: Bucket Sample Locations: Sta. 5+15.80 Placement Location: Manhole, Sanitary Sewer along N perimeter. Specification 3-5 4-6 Date Tested Test Method ASTM C143 ASTM C231 ASTM Cl 064 ASTM Cl 064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 1 1 6.00 28.27 02/16/2006 7 138,400 4,890 1 2 6.00 28.27 03/09/2006 28 178,090 6,300 1 3 6.00 28.27 03/09/2006 28 168,940 5,970 Average (28 Days) 6,140 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Burl E. Thomas Report Distribution: (1) Transwestern Commercial Services (1) TechniStructures [L~/~j (1) City of Coppell TX (1) Rogers O*Brien Construction Co Reviewed by: (1) City of Coppell TX Hussein H. Abusaad, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0075 Service Date: January 14, 2006 ']rEffacon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 7:13am Plant: On-site Supplier: Potter Concrete Truck No: 112 Ticket No: 10212 Mix I.D. No.: 7723 Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 4.3 Concrete Temperature,o F: 64 Ambient Temperature,o F: 35 Plastic Unit Weight, pcf: 144.8 Laboratory Test Data Set Specimen Diameter No. Sample Information Date Cast: January 14, 2006 Time: 7:22am Technician: Daniel J. Drogos Weather Conditions: Cold and dear Accumulative Yards: 140 Placement Method: Direct Discharge Sample Locations: See attached sketch for Location #1 Placement Location: Pavement, NW Parking Lot Specification Date Tested Area ID (inches) (sq. inches) 1 1 6.00 28.27 01/21/2006 7 118,640 4,200 1 2 6.00 28.27 02/11/2006 28 152,240 5,380 1 3 6.00 28.27 02/11/2006 28 155,440 5,500 Average {28 Days) 5,440 1 4 6.00 28.27 03/11/2006 56 168,630 5,960 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0075 Service Date: January 14, 2006 'lrefracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Ma terial Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 9:30am Plant: On-site Supplier: Potter Concrete Truck No: 106 Ticket No: 10229 Mix I.D. No.: 7723 Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 4.7 Concrete Temperature,o F: 65 Ambient Temperature,o F: 51 Plastic Unit Weight, pcf: 145.6 Laboratorv Test Data Set specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Sample Information Date Cast: January 14, 2006 Time: 9:55am Technician: Daniel J. Drogos Weather Conditions: Sunny and cool Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: See attached sketch for Location #2 Placement Location: Pavement, NW Parking Lot Specification Date Tested Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 01/21/2006 7 112,340 3,970 02/11/2006 28 153,820 5,440 02/11/2006 28 152,530 5,390 Average (28 Days) 5,420 03/11/2006 56 160,240 5,670 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0075 Service Date: January 14, 2006 ' rEffal:on 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:32 Plant: On-site Supplier: Potter Concrete Truck No: 119 Ticket No: 10237 Mix I.D. No.: 7723 Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 4.1 Concrete Temperature,~ F: 68 Ambient Temperature,o F: 61 Plastic Unit Weight, pcf: 144.0 Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 Sample Information Date Cast: January 14, 2006 Technician: Daniel J. Drogos Weather Conditions: Sunny and clear Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: See attached sketch for Location #3 Placement Location: Pavement, NW Parking Lot Time: 11:05am Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM Cl 064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/21/2006 7 106,060 3,750 02/11/2006 28 149,540 5,290 02/11/2006 28 142,100 5,030 Average (28 Days) 5,160 03/11/2006 56 158,420 5,600 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Daniel J. Drogos Repod Distribution: (1) Transwestern Commercial Services (1) TechniStructure$ ~J (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by: (1) Cily of Coppell TX Hussein H. Abusaed, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the uae of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ;:1 AT ] · EXIS Il:z; ~: ~L_~ fl/70' L. x 12' ". ~ ~ ~ORE~ W^LL ~ u,~..---3~ TALL, ~' SQ. T~ER ~_ ~EL LISNT ~OLE _ _ ~ 2~1~ .... ~;~ ~--~ H.~ .............................. FIXTU~5, ~? 24' WIDE FIRE LANE 70' L x 12' H. ,A2.204 I L X t2' H. .... "SCREEN WALL 24' WIDE FIRE LANE CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418.0071 Service Date: January 13, 2006 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: David Gunderson 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date:March 13, 2006 Project: AmberPoint Business Park Buildings 4, 5 and 6 505 South Royal Lane Coppell, TX Project No.: 94051418 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:30am Plant: 27 Supplier: Southern Star Truck No: Ticket No: 1016243 Mix I.D. No.: 7723 WaterAdded Onsite Before Test: 0Gallons Water Added Onsite After Test: 5 Gallons Field Test Data Test Result Slump, inches: 4.50 ,&ir Content, %: 5.4 Concrete Temperature,o F: 61 Ambient Temperature,o F: 59 Plastic Unit Weight, pcf: 144.0 Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Sample Information Date Cast: January 13, 2006 Technician: Kudret Aksu Weather Conditions: Clear Accumulative Yards: 10/60 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Pavement Time: 11:35am Specification 3-5 3-5 Date Tested Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 01/20/2006 7 116,290 4,110 02/10/2006 28 131,830 4,660 02/10/2006 28 151,530 5,360 Average (28 Days) 5,010 03/10/2006 56 158,960 5,620 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Kudret Aksu Repod Distribution: (1) Transwestem Commercial Services (1) TechniStructures (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by: (1) city of Coppell TX Hussein H. Abusaad, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s} referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. SIGN '1 ~L__~ ~?0 Lxl2 H. ~, ~ I~c"EE" wA'L ~ u,~30 TALL, ~,' 5~, T~N~O~ER F[~U~, TYP. 24' WIDE FIRE LANE 70' L. x 1E H. L. x 12' H. .... $ORF~N WALL 24' WIDE FIRE LANE I]]TF'FI~I-FI-I~']TFFIfl~FI-I-ITFEI'TT'