Park West CC(02-2)-LR060313,RT OF LABORATORY COMPACTION TEST
I%;i, W=,~enter
Beltline Road and Airline Road
Coppell, Texas
'l 4' p
REPORTED TO: Cadence McS )orporation
14860 Montfort Drive, Suite 270
Dallas, Texas 75254
ATTN: Mr. Bobby Paret
REPORT NO. 231
REPORT DATE: 03-13-06
REG PROJECT NO. 12468
SAMPLE DATE: 02-23-06
CONTRACTOR: Cadence McShane Corporation
Curve Optimum Maximum
No. Soil Classification Proctor Type Moisture, % Density, pcf
Brown clay (lime-
6 treated/ ASTM D-698 17.8 100.9
101.0
1oo.8
~u~ 100.0
99.5
99.0
98.5
98.0
14.0
---1
16.0 18.0 20.0 22.0
Moisture Content (%)
4.5
4.0
3.5
oE3.
2.5
2.0
1.5
1.0
14.0
16.0 18.0 20.0
Moisture Content (%)
22.0
Mail
Distribution: (1)
(1
(1
(1
(1
(1
Cadence McShane Corporation/
Mr. Bobby Paret
Commerce Construction Co., LP/
Mr. Rick Wyly
City of Coppell/Mr. Larry Davis
City of Coppell/Mr. Lee Stone
Northwestern Investment Mgmt./
Mr. Ernest Willmore
Stewart Consulting Associates/
Mr. Mike Smith
Submitted by:
REED ENGINEERING GROUP, LTD.
Original Signed By
Bill Woolwine
Sr. Manager, C.M.T.
BW/cdl