Vista Point II 3-7-LR051031]144(}Rccdm Rd - I)dlas, [X7522(I
(214) 352 4100.Imx(2~4}!52 4Sll
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Scott & Reid Gcaera] ( om ~n~[s~ ]m Sample Date:
~ ~ M05~S4~
PROJECT: ~ista Point II lots ~ , Project No.:
Iex~isville (oppcll,
CONCRETE INFORMATION
CONTRACTOR: Garland Concrete
TICKET NO,: 157861
AMBIENT TEMP. (°F): 68
CONCRETE TEMP. (°F): 72
TIME BATCHED: 9:00 arn
TIME SAMPLED: 9:35 a m
WEATHER CONDITION: Clear
LOCATION OF PLACEMENT:
CONCRETE SUPPLIER: Nelson Bro
PLANT/TRUCK: 01 / 219
MIX ID NUMBER: PD37AEA
AIR (%) (ASTM C-23~)
WATER ADDED (gal): 4
SLUMP (inches) (ASTM Cd43) 2 1/~
Paving, south bound MacArthur Boulevard deceleration lane to north approach
(north point to 20' south)
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12", 28.27 square inches
CYLINDER AGE DATE
NUMBER (Days) TESTED
~ ._7 _ . 10/31,05
lB 28
1 C 28
! D Hold
11/21/05
11/21/05
Hold
TOTAL LOAD
(Pounds)
105840
132870
COMPRESSIVE
STRENGTH
(psi)
3740
4700
138050
AS,M ,¢ 3: Testing Methods ASTMC 143 ASTMC 39
SPECIFIED COMPRESSIVE
STRENGTH
(psi)
4200 / 28 days
J'ocJqlq]clan: Moc N/lUl]l;1
~acheco Koch Consulting Erg~r'eers Enk Hauglie P E
San Saba Construction, Inc Robert !{eserra
City 3fCoppell Larry Davis
FARGO CONSUI,TANTS, INC.
('hocked By: ~
/