Vista Point II 3-7-LR050928[440Rccde~ Rd · Dalkts, tX 75229
1214) 3524100'FtxCc] J q24S/1
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Scml& Rekl General ('onti-aclors, lnc
PROJECT: \rista ['oint II lots 3 ?
Ice, isxilh: Copp~_;ll, '1 c×as
CONCRETE INFORMATION
CONTRACTOR: Garland Concrete
TICKET NO.: 156759
AMBIENT TEMP. (°F): 94
CONCRETE TEMP. (°F): 90
TIME BATCHED: 11:07 a m
TIME SAMPLED: 1217 p m
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Sample Date: 09,21'05
Project No.: M)5 842
CONCRETE SUPPLIER: Norson Brothers
PLANT/TRUCK: 1 / 219
MIX ID NUMBER: PD37AEA
AIR (%) (ASTM C-231) 3.8
WATER ADDED (gal): 0
Clear SLUMP (inches) (ASTM C-143) 2
Paving, MacAurthur Boulevard north bound loft turn lane, 20' north from south point
of turr~ lane
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12", 28.27 square inches
~'YLikDER ~ ' AGE
NUMBER i (Days)
iA
IC 28
iD i Hold
Curing:
DATE
TESTED
TOTAL LOAD COMPRESSIVE
(Pounds) STRENGTH
(psi)
SPECIFIED COMPRESSIVE
STRENGTH
(psi)
9/28/05 114410 4050 4200 / 28 days
1019/05 143520 5080
10"19/05 146000 5160
ASTMC 14 ASTMC 39
Hold
Scc!t &Reic General Cs,/tractors !r/C KO'my Newmar/
F~RGO CONSULTANTS, IN(.
(~ccked By~