Loading...
Vista Point II 3-7-LR050811 [1~40 Reedcr Rd · [)arias, IX 75229 Icl /2141 3~2-4~01} · },ax 1214) 352 4811 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Scott & Reid GcnerM ( ontraclo -s, lnc Sample Date: 08/04/05 PROJECT: Vista Point Il Lots 3 7 Project No.: M05-842 LewisviIle ,' Coppell, Texas CONCRETE INFORMATION Harrison Structures 7155144 96 93 12:40 p.m 1:10 p.m Partly Cloudy CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231) WATER ADDED (gal): SLUMP (inches) (ASTrv1 C-143) CONTRACTOR: TICKET NO.: LMC AMBIENT TEMP. (°F): 7 / 5016 CONCRETE TEMP. (°F): 1701 TIME BATCHED: TIME SAMPLED: 5 WEATHER CONDITION: I Y~ LOCATION OF PLACEMENT: Sanitary Sewer Manhole, Line SS~I station 5+00 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER AGE DATE TOTAL LOAD COMPRESSIVE SPECIFIED COMPRESSIVE NUMBER (Days) TESTED (Pounds) STRENGTH STRENGTH (psi) (psi) lA 8/11/05 118170 4180 1B 28 9/01/05 147850 ,5230 I C 28 9/01/05 144980 5130 1D Hold Hold Specifications: Making & ASTM C-31 Testing Methods: ASTM C-143, ASTM C-39 Curing: 4200 / 28 days _ lechnicmn: MoeMunim FARGO CONSULTANTS, IN(;. Checked By:/7~ Scott & Reid General Contractors. IRc. Kenny Newman Pacheco Koch Consulting Engineers Erik Haug[ie, P E San Saba Construction, Inc. Robert Beserra (Pity of Coppell - Larry Davis