Amberpoint BP 2R-LR060331FIELD DENSITY TESTING Report Number: 94051418 0313 lferr~con 8901 Carpenter Fnnry, Ste #100 Service Date: March 24, 2006 Dallas, Texas 75247 (214) 630-1010 Client: Report Date; March 31, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn• David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.: 94051418 Material Information Material Laboratory No Test Method Description and Classification 1 514180069 ASTM D 698 Brown and gray clay w/sand (lime treated) 2 514180270 ASTM D 698 Brown clay (lime treated) Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elev No. (inches} Plumbing, Building #5 624 Retest for Test #620, dated 03/23/06 625 Retest for Test #621, dated 03/23/06 626 Retest for Test #622, dated 03/23/06 627 Retest for Test #623, dat / / 628 B 8/2 5 629 B.8/4 630 8.8/12.5 631 8.8/3 5 632 A.5/6 8 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (°,6 compaction) 3' BFG 1 6 28 0 '` 93.0 95 2' BFG 1 6 27.3 * 92 0 94 Final 2 6 24 8 97 5 98 Final 2 6 23.4 961 96 Final 2 6 25.1 * 98.6 99 2' BFG 1 6 26.1 * 92.5 95 Final 2 6 22.8 97.2 97 Final 2 6 22.3 94 7 95 3' BFG 1 6 25.9 * 91.1 93 Datum: BFG =below final grade Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test MethodASTM D2922, ASTM D3017 Y J Technician' Barry Cuble ~ Field Results Reported To• Jeff with Rogers O'Brien Report Distribution. (1) Transwestern Commercial Services (1) TechniStructu (1) City of Coppell TX (1) Rogers O'Brie onstruc ion Co Reviewed by: (1) City of Coppell TX (1) O'Brien 8 Assoc Hussein H Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Lab Test Data Proiect Requirements Optimum Max. Lab Water Dry Unit Water Minimum Dry Content Weight Content Unit Weight (%} (pCf) (%) (°h compaction) 24 3 97 7 >/_ +4 92 21 9 99 7 -1/+3 95 Page 1 of 1 DJ-ACSiROI-F;~;~re Hay FIELD DENSITY TESTING b 94051418 0296 l~erracon Report Num er 8901 Car enter F Service Date March 17, 2006 p rwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client Report Date. March 31, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No 94051418 Lab Test Data Proiect Requirements Material Information Optimum Max. Lab Water Dry Unit Water Minimum Dry Material Laboratory Content Weight Content Unit Weight No Test Method Description and Classification (%) (pcf) (%) (°~ compaction) 1 514180288 ASTM D 698 Light brown sandy clay (lime treated) 24 9 95 1 -1/+2 95 Field Test Data Probe Test Lift/ Mat Depth No Test Location Elev No (inches) Building #6 618 Retest of Test #610, dated 03/16/06 FG 1 6 619 Retest of Test #615, dated 03/16/06 FG 1 6 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (°k compaction) 25 1 94 7 100 24 8 93 6 98 Datum FG =final grade Comments Test results on this report meet project specification Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition Field Test MethodASTM D2922, ASTM D3017 Technician Francisco Morillo Field Results Reported To James, Superintendent Report Distribution (1) Transwestern Commercial Services (1) TechniStructures Z (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by' (1) City of Coppell TX Hussein H Abusaad, P E. (1) O'Brien 8 Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ORACS~ROi-FN~~e key