Loading...
Denton Tap 3A-LR060407SAM ENGINEERING TESTING, L.P. Serving The Geo- Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790 -1910 FAX: (972) 790 -0967 Materials Testing CONCRETE PLACEMENT INSPECTION STRENGTH TEST REPORT Geotechnical Environmental CLIENT: PROJECT: ATTN: Head Construction, Inc 3030 LBJ, Ste. 700 Dallas, TX 75234 Ken Head SE &T TECHNICIAN: Bryan Butler LOCATION OF PLACEMENT: Proposed Coppell Montessori Acade y� 136 Fitness Coppell, TX Southeast Entrance 9 II` aoy Time Arrived: 2:35 PM Time Left: 5'02 PM Slum. (Inches) 4 Concrete Tem •erature (F 83 Air Content: 5 Total No of Test C linders Made. 4 Total Cubic Yards Placed: 20 Added Water: N/A Weather Conditions: Partl Cloud Warm Air Tem erature F): 75 Unit Weis ht of Fresh Concrete: 145 2A 2B 2C 2D 7 14 28 28 3/14/06 3/21/06 4/4/06 4/4/06 Curing ASTM C -31 Slump ASTM C -143 149 149 149 149 80,000 109,000 122,000 126,000 Test Method ASTM C -39 231 STANDARD 6" X 12" AREA 28.27 SQ. IN. REPORT DATE:4/7 /06 SAMPLE DATE: 3/7/06 PROJECT NO.: 817TXIK5 REPORT NO.: 5 PAGE 1 OF 1 Concrete Su lier: TX' Ticket 216426 Truck 737 Time Batched* 319 PM Time Sam led: 4:15 PM Product Code: 8274 Cement: N/A Fl Ash' N/A Coarse A• re •ate. N/A Water: N/A Air Content N/A 2829 3856 4314 4456 MEMO Cylinder Made By SE &T 3600/28 3600/28 3600/28 3600/28 Cylinders Tested By SE &T Remarks Tested concrete meets /exceeds required strength. Very Truly Yours, Sadik (SAM) Al- Musawe, M Sc Ph D P E. Civil Environmental Engineer Texas Registration Number 61893 This report is for the sole use of the client addressed The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples G. /Cpistr /Cpistr5 /MG Failure Investigation