Amberpoint BP 2R-LR060411FIELD DENSITY TESTING
Report Number: 94051418 0263
Service Date: March 10, 2006
l~~rr~con
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Report Date: April 11, 2006
Transwestern Commercial Services Project: AmberPoint Business Park
Attn: David Gunderson Buiidings 4, 5 and 6
5001 Spring Valley Rd Ste 600 W 505 South Royal Lane
Dallas TX 75244 Coppell, TX
Project No.: 94051418
Material Information
Material Laboratory
No Test Method
escription and Classification Lab Test Data
Optimum Max. Lab
Water Dry Unit
Content Weight
(%) (pcf) Project Requirements
Water Minimum Dry
Content Unit Weight
(%) (°k compaction)
1 514180270 ASTM D 698 Brown clay (lime treafed) 21 9 99 7 -1/+2 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No Test Location Elev No. (inches) (%) {pcf) (% compaction)
Building #5
582 25' N & 25' E of SW corner FG 1 6 20.9 95 6 96
583 30' N & 100' E of SW corner FG 1 6 21.2 97.1 97
584 30' N & 210' E of SW corner FG 1 6 20 9 98.7 99
585 50' N & 300' E of SW corner FG 1 6 21.8 96.4 97
586 75' N & 50' E of SW corner FG 1 6 22.0 97 0 97
587 75' N & 150' E of SW corner FG 1 6 22.6 95 5 96
588 75' N & 200' E of SW corner FG 1 6 21.4 98 3 99
Datum: FG =final grade
Comments
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test MethodASTM D2922, ASTM D3017
Terracon Rep: Francisco Morillo
Field Results Reported To: Superintendent
Report Distribution: L
(1) Transwestern Commercial Services (1) TechniStructures C/~~-~/
(1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by:
(1) City of Coppell TX
(1) O'Brien 8 Assoc Hussein H Abusaad, P E.
Senior Project Manager
The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1