ST9902-CS060120
Jan ~u ~UUo ~:26AM
REDIX-MIX CONCRETE
8174855985
p.2
.-MIX
~
CLIENT: nSEOPAVlNG
Jouary 20, 2016
PROJECT: WEST SANDY LAKE ROAD, COPP.ELL
MIX SPECIFICATIONS:
Pwx NO. 728/
APPLICATION:
REQUIRED STRENGTH
PLACEMENT SLUMP
WIC RATIO
AIR CONTENT
MAXIMUM TEMPERATURE
FLATWORK
3600 PSI @ 21 DAYS
. INCH +1- 1
0.48 LBlLB
U +/- 1.5".
95DWUFS F
MATERIALS ASTM STANDARDS
CEMENT ASTM C150 TYPE IIII
FLYASH ASTM C618 CLASS F
COARSE AGG. ASTM C33 SIZE NO. 57
COARSE AGG. ASTM OJ SIZE NO.
LIGHT WEIGHT ASTM C3JO
FJNEAGG. ASTM C33
FINE AGG. ASTM C33
ADMIXTURE ASTM C494 TYPE A or D
ADMIXTURE ASTM C494 TYPE F
ADMIXTURE ASTM C160
WATER
WEIGHTS(SSD}
VOLUME
517
2.63
000
0.00
1860
11.12
000
1290
7.86
3 - 6 ozIcwt
00.0
.25 - 4 rRicwt
1.35
4.04
27.00
m
ASTM C94 STANDARD SPECIFICA noNS FOR READY-MIXED CONCRETE STATES AS FOLLOWS:
"WHEN THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE, THE MANUFACTURER.
SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS
CONCRETE MUST BE CERTIFIED ACI LEVEL L ..
ADDITIONA.L WATER ADDED TO THIS CONCRETE JI'.lLL AEDUCE THE STItENGTB. ANY WATER ADDED IN
EXCESS OF SPECIFIED SLUMP IS A.T CUSTOMEIlS RlSL