Loading...
ST9902-CS060120 Jan ~u ~UUo ~:26AM REDIX-MIX CONCRETE 8174855985 p.2 .-MIX ~ CLIENT: nSEOPAVlNG Jouary 20, 2016 PROJECT: WEST SANDY LAKE ROAD, COPP.ELL MIX SPECIFICATIONS: Pwx NO. 728/ APPLICATION: REQUIRED STRENGTH PLACEMENT SLUMP WIC RATIO AIR CONTENT MAXIMUM TEMPERATURE FLATWORK 3600 PSI @ 21 DAYS . INCH +1- 1 0.48 LBlLB U +/- 1.5". 95DWUFS F MATERIALS ASTM STANDARDS CEMENT ASTM C150 TYPE IIII FLYASH ASTM C618 CLASS F COARSE AGG. ASTM C33 SIZE NO. 57 COARSE AGG. ASTM OJ SIZE NO. LIGHT WEIGHT ASTM C3JO FJNEAGG. ASTM C33 FINE AGG. ASTM C33 ADMIXTURE ASTM C494 TYPE A or D ADMIXTURE ASTM C494 TYPE F ADMIXTURE ASTM C160 WATER WEIGHTS(SSD} VOLUME 517 2.63 000 0.00 1860 11.12 000 1290 7.86 3 - 6 ozIcwt 00.0 .25 - 4 rRicwt 1.35 4.04 27.00 m ASTM C94 STANDARD SPECIFICA noNS FOR READY-MIXED CONCRETE STATES AS FOLLOWS: "WHEN THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE, THE MANUFACTURER. SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS CONCRETE MUST BE CERTIFIED ACI LEVEL L .. ADDITIONA.L WATER ADDED TO THIS CONCRETE JI'.lLL AEDUCE THE STItENGTB. ANY WATER ADDED IN EXCESS OF SPECIFIED SLUMP IS A.T CUSTOMEIlS RlSL