SS9901-LR051128T Texas CMT Inc. Construction Materials Testing and Environmental Consulting 10044 Monroe Drive Dallas, Texas 75229 (214) 352 -6957 Fax (214) 352 -6972 www texascmt.com REPORT OF CONCRETE MIX OBSERVATION Report Date November 28, 2005 Date Concrete Placed. October 27, 2005 Standard 6 "x12" Client: City Of Coppell Area 28.27 Square Inches Project: DeForest & Sandy Lake Wastewater Concrete Report No 23 Lift Stations Project SS 99 -01 Contractor Can -Fer Construction Project No 205 -0126 Concrete Supplier and Plant. Southern Star 29 Location of Placement: Slab MATERIALS Source/ SSD Batch Wts. OBSERVATION DATA Description (Lbs /CuYd) Mix Number 7503 Time Sample Batched. 08 am Cement: Time Sampled. 0905 am •cen.artcs Sample Location. Center of electrical foundation slab, north of Fly Ash. 11/03/05 pump station Coarse Aggregate Truck /Ticket No 902/953971 Intermediate Aggregate Temperature - 11/24/05 Fine Aggregate Ambient Range 60 °F Concrete Range 75 °F Admixtures Slump Range (inches) 4 1 /2" 1 Weather Conditions. Clear 2 Time Started. 0700 am Added Water 0 gallons Time Completed. 10.30 am Sample Air Content ( %) N/A Total Cubic Yards Placed. 20 Test Methods Utilized RPm6-1 qt—oth (I hs kri in 1• dOOO Specimen Number =Meas.r Age (Days) Date Tested To tal Load (Lbs.) Compressive Strength (Lbs. /5 .ln.) •cen.artcs DLS 85 7 11/03/05 148,720 5,260 DLS 86 28 11/24/05 180,040 6,370 t 4/2 DLS 87 28 11/24/05 184,000 6,510 DLS 88 H HOLD Test Methods Utilized Fracture Regular Cylinders Made By AB ASTM C -31,C 39,C 143 (Unless Noted Otherwise) Remarks and /or Distribution. * Superintendent informed of slump cc Mr Rick O'Dell - City of Coppell Mr Todd C Hoff - Canfer Construction Co Ms Erika K. Cooper - Turner, Collie & Braden Mr Bobby Barr - Onsite cell. 469 -556 -6469 Texas CMT, Inc Reviewed by: J All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of Texas CMT Inc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested andior observed and are not necessarily indicative of the quantities of apparently identical or similar products.