BEI Properties-LR060210Concrete Compression Test Report J~ ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center Report Distribution• (1) CooperGeneral Contractors (1) Ray Mansoory (1) City of Coppell CMJ Report No. 502-5167-012 Report Date: 02/10/2006 Strength 3000 psi @ 28 Days Placement Date 01/06/2006 Stump 3 in min 5 in max Sampled By Richard Jones Air Content n/a Weather Clear/Light Wind Concrete Temperature 55° F min 90° F max Supplier/Mix Beall/330H1521 Ambient Temperature n/a Air Content Method ASTM C231 'y~" ~} ~ ~ '-' Fetd Data Seta` 01 Ticket Number 89050856 Time Batched: 09.17 Time Sampled: 09:55 Slump• 4.5 in Air Content: 1.0 % Unit Weight: N/A Concrete Temperature: 58° F Ambient Temperature: 55° F Yardage (c.y ): 10 of 120 Placement Location. Slab, Entire Slab Sample Location From SE Corner of Slab, 5' N, 5' W Concrete Compression Test Results Set # Cylinder # Test Date Age (days) Max Load (Ibs. force) Area (sq.in.) Stren th (psi Fracture Type 01 BRC01060601 01/13/2006 7 104920 28.27 3710 C-cone/shear 01 BRC01060602 02/03/2006 28 159800 28.27 5650 C-cone/shear 01 BRC01060603 02/03/2006 28 155770 28.27 5510 C-cone/shear 01 BRC01060604 Hold 28 day average 5580 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 10 Gallons of Water Added On-Site, approved by• Gus w/Cooper CMJ Engineering, LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. of Page 1 oft Concrete Compression Test Report ~L • 1 ENGINEERING, INC 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center Report Distribution (1) Cooper General Contractors (1) Ray Mansoory (1 }City of Coppell CMJ Report No.• 502-5167-012 Report Date: 02/10/2006 Specifications Test Data Strength 3000 psi @ 28 Days Placement Date 01/06/2006 Slump 3 in min 5 in max Sampled By Richard Jones Air Content n/a Weather Clear/Light Wind Concrete Temperature 55° F min 90° F max Supplier/Mix Beall/330H1521 Ambient Temperature n!a Air Content Method ASTM C231 RT' S. ~~=:Fiet""C1 Data Se4 2. I„ Ticket Number 89050873 Time Batched: 11.39 Time Sampled: 12:30 Slump: 5 in Air Content: 1.0 % Unit Weight: NA Concrete Temperature: 62° F Ambient Temperature: 58° F Yardage (c.y ): 110 of 110 Placement Location: Slab, Entire Slab Sample Location From NW Corner, 10' S & 5' E Concrete Compression Test Results Cylinder Age Max Load Area Stren th i Fracture T Set # # Test Date (days) (Ibs. force) (sq.in.) (ps ype 02 BRC01060605 01/13/2006 7 118980 28.27 4210 B-cone/split 02 BRC01060606 02/03/2006 28 159840 28.27 5650 C-cone/shear 02 BRC01060607 02/03/2006 28 158660 28.27 5610 C-cone/shear 02 BRC01060608 Hold 28 day average 5630 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 10 Gallons of Water Added On-Site, approved by' Gus w/Cooper CMJ Engineering, Inc ;arl Lee, S E.T CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. of Page 2 of 2