Loading...
BEI Properties-LR060104Concrete Compression Test Report ~~ ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center CMJ Report No. 502-5167-010 Report Date: 01/04/2006 Report Distribution (1}Cooper General Contractors (1) Ray Mansoory (1) City of Coppell Strength Slump Air Content Concrete Temperature Ambient Temperature 3000 psi @ 28 Days 3 in min 5 in max n/a 55° F min 90° F max n/a Placement Date Sampled By Weather Supplier/Mix Air Content Method 1 2/2 312 0 0 5 Shawn Cook Partly Cloudy/Windy Beall/1521 ASTM C231 Field Data Set #Oi ~ Ticket Number 89050681 Time Batched: 12:24 Time Sampled: 13:29 Slump 3 in Air Content: 1 7 % Unit Weight: n/a Concrete Temperature. 60° F Ambient Temperature. 64° F Yardage (c.y ): 10 of 10 Placement Location: Footings:All Building Footing Pads Sample Location. SW Corner Going North 5 Pads Poured From Truck Concrete Compression Test Results Set # Cylinder # Test Date Age (days) Max Load (Ibs. force) Area (sq.in. Stren th (psi Fracture Type 01 BRC12230501 12/30/2005 7 80820 28.27 2860 C-cone/shear 01 BRC12230502 01/20/2006 28 119740 28.27 4230 C-cone/shear 01 BRC12230503 01/20/2006 28 118170 28.27 4180 B-cone/split 01 BRC12230504 Hold 28 day average 4210 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards. C31, C39, C138, C143, C172, C1064, and C617 or C1231 ~ Gallons of Water Added On-Site CMJ Engineering, Inc ~.m i mai myei LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 01 Page 1 of 1