Loading...
BEI Properties-LR051221J~~ ENGINF,ER[NG, INC Moisture-Density Relationship 7636 Pebble Drive Fort Worth, Texas 76118 Tel (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Repon` Distribution (1) Cooper General Contractors Project: Bloom Retail Center (1) Ray Mansoory (1) City of Coppell CMJ Report No. 502-5167-009 Report Date: 12/21/2005 Project Information Material Origin. Haul In Tested By• Rick Campbell Sample Location In-Place on East Side of Pad Sample Date 12/15/2005 Material Description Tan Clayey Sand Material Use. Select Fill Moisture-Density Relationship -Curve No. 2048 1 1 Dry Density (P~ 11 11 11 23 1 0% Satura ion 21 9 ~ 7 5 6 8 10 12 14 16 18 Moisture Content (%) Material Properties and Test Information -Curve No. 2048 Maximum Dry Density 119 5 Liquid Limit: 22 Optimum Moisture Percent: 11.5 Plastic Limit: 14 Plasticity Index: 8 Test Method(s): ASTM D-698, ASTM D4318 Rammer Description: Mechanical Preparation Procedure. Moist CMJ Engineering, Inc LIMITATIONS• The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 06 Page 1 of 1