Loading...
BEI Properties-LR051215In-Place Soil Moisture/Density Tests by Nuclear Method ~~~ ENGI:N.EERW~G, iNC 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817} 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center CMJ Report No. 502-5167-004 vo..~.-r Warn 12/15(2005 Report Distribution (1) Cooper General Contractors (1 }Ray Mansoory (1) City of Coppell ...-r.,.. _-_._ Specifications _, Test Data Percent Compaction +92% min +96% max Date Tested 12!0912005 Moisture Content: opt +3% or above Technician Rick Campbell f _ - ~ Material'Reference Curare Data " ~ ~ Optimum Maximum Dry Curve No Test Method Material Description Moisture % Density pcf 2015 ASTM D-698 Dark Brown Clay 24 0 95.5 In-Place Test Results Ref Probe Percent Wet Density Dry Density Percent Test No Elevation or Lift Location . Curve Depth Moisture (pcf) (pcf) Density M/C Subgrade for Bldg. Pad** 1 1 Subgrade Retest of #1.0 Report #502-5167-003 2015 6" 22.7' 104 7 85 3 89.3 2 1 Subgrade Retest of #1 1 Above 2015 6" 27.2 114 6 90 1 94.3 ' . 1 2 Subgrade Retest of #2.0 Report #502-5167-003 2015 6" 18.7"` 97 7 82.3 86.2 . 2 2 Subgrade Retest of #2.1 Above 2015 6" 28.0 113.5 88.7 92.9 . 3 1 Subgrade Retest of #3 0 Report #502-5167-003 2015 6" 23.3' 112.6 91 3 95.6 2 3 Subgrade Retest of #3.1 Above 2015 6" 27 9 113.6 88.8 93.0 . 4 0 1st Lift 30' South, 10' West from NE Corner of Pad 2015 6" 28.6 113.4 88.2 92.4 5 0 1st Lift 15' South, 15' East from NW Corner of Pad 2015 6" 29 0 114 7 88.9 93.1 0 6 1st Lift 20' North, 10' East from SW Corner of Pad 2015 6" 28.5 113 3 88.2 92.4 . 7 0 2nd Lift 10' South, 15' East from NE Corner of Pad 2015 6" 24 6" 110.9 89.0 93.2 8 0 2nd Lift 30' North, 10' East from SW Corner of Pad 2015 6" 19.5" 109.0 91.2 95.5 An asterisk (") appears next to test results which do NOT meet the project specifications. Test Method(s}• ASTM D2922, ASTM D3017 * Non-Compliant: Sub-Contractor, Ralph with C I Hone, was Notified *" Moisture/Conditioned Subgrade and Fill for Building Pad Retest of Report #502-5167-003, Date Tested 12/07/2005 Gauge Humboldt Gauge SN 4953 Std Density Count: 3808 ~ Steven S ~hnston CMJ Engineering, Inc ! CMT Manager LIMITATfONS The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. page 1 of 1 o~ In-Place Soil Moisture/Density Tests by Nuclear Method J~ PNG}N:EF..IZING, INC 7636 Pebble Drive Fort Worth, Texas 76118 Tel. (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Report Distribution (1) Cooper General Contractors Project: Bloom Retail Center (1) Ray Mansoory (1) City of Coppell CMJ Report No. 502-5167-006 Report Date. 12/15/2005 Specifications Test Data 'ercent Compaction +92% min +96% max Date Tested 12/12/2005 vloisture Content: opt +3% or above Technician John Reid Curve No Test Method 2015 ASTM D-698 In-Place Test Results Optimum Maximum Dry Moisture % Density pcf 24 0 95.5 Test Elevation Ref Probe Percent Wet Density Dry Density Percent No or Lift Location Curve Depth Moisture (pcf) (pcf) Density M/C Fill for Bldg. Pad ** 13 0 Final 15' North, 15' West of SE Corner 2015 6" 29.3 114.3 88.4 92.6 14 0 Final 40' North, 40' West of SE Corner 2015 6" 28.1 115.4 90 1 94.3 15.0 Final 15' South, 15' East of NW Corner 2015 6" 27 6 114.3 89 6 93.8 Test results on this report meet project specification. Test Method(s): ASTM D2922, ASTM D3017 ** Moisture-Conditioned Fill for Building Pad Gauge CPN Gauge SN 6660 ' Material Reference Curve Data: Material Description Dark Brown Clay Std Density Count: 59825 CMJ Engineering, Inc / st~~n S Johnston CMT Manager LIMITATIONS The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for e exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. o~ Page 1 of 1 In-Place Soil Moisture/Density Tests by Nuclear Method ]~ ENGIN:EFRII~iG, [NC 7636 Pebble Drive Fort Worth, Texas 76118 TeI (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center Report Distribution (1) Cooper General Contractors (1) Ray Mansoory {1) City of Coppell CMJ Report No. 502-5167-005 Report Date 12/15/2005 Specifications Test Data Percent Compaction +92% min +96% max Date Tested 12/10/2005 Moisture Content: opt +3% or above Technician Rick Campbell Material Reference Curve Data Optimum Maximum Dry Curve No. Test Method Material Description Moisture % Density pcf 2015 ASTM D-698 Dark Brown Clay 24 0 95.5 In-Place Test Results Test Elevation Ref Probe Percent Wet Density Dry Density Percent No or Lift Location Curve Depth Moisture (pcf) (pcf) Density M/C Subgrade for Bldg. Pad** 7 1 2nd Lift Retest of #7 0 Report #502-5167-004 2015 6" 27 8 113.6 88.9 93.1 8.1 2nd Lift Retest of #8.0 Report #502-5167-004 2015 6" 29.5 114 1 88 1 92.3 9.0 2nd Lift 20' North, 10' West from SE Corner of Pad 2015 6" 29 1 114.9 89.0 93.2 10 0 3rd Lift 15' South, 15' East from NW Corner of Pad 2015 6" 27 9 112.7 88.1 92.3 11 0 3rd Lift 20' South, 10' West from NE Corner of Pad 2015 6" 30.5 114 7 87.9 92.0 12.0 3rd Lift 20' North, 15' East from SW Corner of Pad 2015 6" 29 4 114 1 88.2 92.4 Test results on this report meet project specification. Test Method(s): ASTM 02922, ASTM 03017 Retest of Report #502-5167-004, Date Tested 12/09/2005 *'` Moisture/Conditioned Subgrade and Fill for Building Pad Gauge Humboldt Gauge SN 4953 Std Density Count: 3808 Std CMJ Engineering, Inc / Steven S Johnston CMT Manager LIMITATIONS The test results presented in this report apply only to the specific samples, items, and areasfdescribed within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. o~ Page 1 of 1