Loading...
Villas at LV-LR05110811/15/2005 11:42 9724068023 A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620 -8911 ALPHA TESTING INC PAGE 02/02 r° Concrete Compression Test Report Tested For WPC 2004 COPPELL, L.P % OOWDEY, ANDERSON 8 ASSOCIATES Our Report No,. 051$2.74 ATTN, RODNEY LOUVIERE Issue Date: I V06/2005 5225 VILLAGE CREEK DRIVE, SUITE 200 PLANO,TX 75093 Fax Number: (000) 000 -0000 Project Dose: VILLAS AT LAKE VISTA PHASE ONE SE CORNER OF MACARTHUR BLVD B LAKE VISTA OR FIELD DATA Placement Location INLET TOPS, LINE A ® STATION 3 *83 Date Placed 10/05/05 Time Placed: 1 20 PM Slump (ASTM C -143): 3,0 Air Content: 4.5 (ASTM C -173) Air Temperature: 83 Specimen Temperature: 76 Date Received: 10/06/05 Delivery Method: PICKED UP BY ALPHA Field Dab Submitted By: ALLEN, DUSTIN Mix Data Submitted By: REDI -MIX Plant Number; 1 -4000 Delivery Ticket No. 155015 Made By: ALPHA Cured Specification: ASTM C -31 CYLINDER COMPRESSION TEST RESULTS Lab No. Cure Type: Cap Sec: Data Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. Im. Max Load: PSI: 142 LAB C -1231 10/12/05 7 12 N/A 6 28.27 98250 3480 143 LAB C -1231 11/02/05 28 12 N/A 6 28.27 131650 4860 144 LAB C -1231 11/02/05 28 12 NIA 6 28.27 137210 4850 145 LAB HOLD HOLD 12 NIA 6 28,27 0 Specifications -- - 26 30001 Results to Date- PASS CC. WPC 2004 COPPELL. L.P HAWKINS - WELWOOD HOMES L.P, CITY OF COPPELL, LACY CONSTRUCTION Respectfully Submltted By of Alpha Testing Inc. Our left remult% and reports are for the eXCItisNe use of Il+e talent (end IhfHr deNgnaled reoepienis on file in our office) and shall not tae reproduced and/or olslrlouled except with express approval of ALPHA. The u-te of our name and test resulls must receive our written 80f0val Test reslllls and n`pons apply only to the Sanlp4s tested and /or o0serveo, and are not Indicative of the qualities of apparently identical or similar specimens, Geotechnlcal Engineering • Construction Materials Testing' Environmental Engineering • Consulting 49588