Villas at LV-LR05110311/09/2005 12:35 9724068023
A ALPHA
TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620 -8911
ALPHA TESTING INC
PAGE 02/02
Concrete Compression Test
Report
Taxied For WPC 2004 COPPELL. L.P. % DOWDEY, ANDERSON & ASSOCIATES Our Report No.: 05152 -72
ATTN: RODNEY LOUVIERE Issue Data: 11103/2005
5225 VILLAGE CREEK DRIVE, SUITE 200
PLANO, TX 75093
Fax Number: (000) 000.0000
Protect Dose. VILLAS AT LAKE VISTA PHASE ONE
SE CORNER OF MACARTHUR BLVD 6 LAKE VISTA DR
FIELD DATA
Placement Location: INLET BASE & WALLS, LAKE VISTA PLACE Q STATION 4 +00
Deese Placed:
09/30/05
Time Placed:
N/A
Slump (A8TM C -143):
N/A
Air Content:
N/A
Air Temperature:
N/A
Specimen Temperature:
N/A
Dace Received:
10/03/05
Delivery Method:
PICKED UP BY ALPHA
Field Data Submitted By
CONTRACTOR
Mix Data Submitted By:
NIA
Plant Number' N/A
Delivery Ticket No.: N/A
Made By: CONTRACTOR
Cured Speelfleation: ASTM C -31
CYLINDER COMPRESSION TEST RESULTS
Lab
No.:
Cure
Type:
Cap
$ c:
Date
Tested:
Age
Di :
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Ana:
Sq. In.
Max
Load:
PSI:
130
LAB
C -1231
10/07/05
7
12
WA
6
28.27
121320
4290
131
LAB
C -1231
10/28/05
28
12
N/A
6
28.27
154590
5470
132
LAB
C-1231
10/28/05
28
12
NIA
6
28.27
154530
5470
133
LAB
HOLD
HOLD
12
N/A
6
28.27
0
specifications: 28 3000
Results to Date: PASS
CC WPC 2004 COPPELL, L.P , HAWKINS - WELWOOD HOMES. L.P. CITY OF COPPELL. LACY CONSTRUCTION
Respectfully Submitted By of Alpha Testing, Inc
Oct teat results and reports are for the exclusive use or me Client (end their designated recsplentS on Ate In our office) and shall not be repmdumd and/or distributed
except with express approval of ALPHA. The use of our name and test results Mutl elleo @ our wrfnen approval. Test results and rr pons apply only to the samples
tested and /or observed Warp not Indicative of the Qualities of apparently iderttieil or similar specimens,
Geotschnical Engineering' Construction Materials Testing' Environmental Englnsering 11 consulting 46501