WA9701-LR0604208908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
7701 N1 Little York, Ste 600, Houston, TX 77040
Corporate Phone: (214) 630 -9745
IN -PLACE DENSITY TES
Client: City of Coppell
Report No.:
254459
Ms Suzan Taylor
Project No.:
0511107
PO Box 9478
Date of Service:
04/13/2006
Coppell TX 75019
Report Date:
04/20/2006
Project- Denton Tap Road
16" Waterline
Coppell, Texas
Services. Perform In -Place Density Test in accordance with ASTM Standards.
PROJECT DATA
CONTRACTOR. J T Dersner, Inc. Standard Counts
ASTM D -2922
Test Methods: Gauge: Troxler 3430 Moisture Density
ASTM D -3017 Gauge Serial No: 35518 Current: 738 Current: 2571
Test Mode: BS
Previous: 739 Previous: 2580
MOISTURE DENSITY RELATIONS
Maximum Project Requirements
M/D No. Description Moisture % Density pcf Moisture Density
1 Crushed Limestone w /Clayey Sand
8.5 133 0 Optimum +4 95 min
TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY
NO TEST LOCATION DEPTH No. ( %) (pcf) (pcf) (% max)
Flex base
16" water line, Station 0 +50 0" 1 97
Test results on this report meet project specification.
Technician. Joe Jernigan
Report Distribution.
(1) City of Coppell
(1) City of Coppell
Started. 7.30am Finished. 9.30am
1387 1264 95
. Scott Watson, AET
CMT Operations Manager
LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
07TAI Page 1 of 1