Vista Point 2R-CS060302 DEVELOPMENT REVIEW COMMIITEE ENGINEERING COMMENTS ITEM: PD-199R3-HC. Vista Point II. Lot 2. Block A, zoning change request from PD- 199-HC (Planned Development-199-Highway Commercial) to PD-199R3-HC (Planned Development-199 Revision 3-Highway Commercial) to attach a Detail Site Plan to allow the development of three buildings containing a total of approximately 115,525- square feet on 10.046 acres of property located along the west side of MacArthur Boulevard, south of S.H. 121, at the request of Christopher Gardner, Jackson Shaw. STAFF REP.: Marcie Diamond PROJECT ID# PD-06-0009 DRC DATE: March 2, 2006 CONTACT: Kenneth M. Griffin, P.E., Dir.of EnJlineerinJ!/Public Works 972/304-3686 COMMENT STATUS: PRELIMINJ' .R.Y o/FINAL REVISED AFTER P&Z Site Plan 1. The fire hydrants on the site plan do not match the utility plan. Additionally, FDC's are not shown on the site plan. The plans should be consistent. DEVELOPMENT REVIEW COMMIITEE ENGINEERING COMMENTS ITEM: Vista Point II. Lot 2. Block A. Replat, to revise the locations ofthe fire lanes to allow the development of three buildings containing a total of approximately 115,525-square feet on 10.046 acres of property located along the west side of MacArthur Boulevard., south of S.H. 121, at the request of Christopher Gardner, Jackson Shaw. STAFF REP.: Marcie Diamond PROJECT ID# RP-06-0010 DRC DATE: March 2, 2006 CONTACT: Kenneth M. Griffin, P.E., Dir.of Engineerinfl/Public Works 972/304-3686 COMMENT STATUS: PRELIMINARY o/FINAL REVISED J'.FnR P&Z Grading and Drainage Plan 1. Additional information will be needed in order to perform a review of the grading and drainage plan. Include drainage areas and calculations on this sheet. Additional comments may be generated upon detailed engineering review. THE C I T Y o F COPPELL ~* " . Proiect ID Address Proiect Tvoe AOolication Date Case Manaaer Proiect Descriotion Agency Building Inspection Electric and Gas Engineering Fire Administration Parks and Recreation Planning Department THE CITY o F CITY OF COPPELL ORC REPORT PD-06-0009 B State Highway 121 Re-Zoning PD 2/15/2006 Marcie Diamond COPPELL Proiect Name PD-199r3-hc, Vista Point Ii, Lot 2R, Block A, zoning change request from PD-199-HC (Planned Development-199-Highway Commercial) to PD-199R3-HC (Planned Development-199 Revision 3-Highway Commercial) to attach a Detail Site Plan to allow the development of three buildings containing a total of approximately 115,525- square feet on 10 046 acres of property 1 of 2 Reviewed By Greg Jones Review Date 2/20/2006 Tim Oates 2/23/2006 John Elias Marcie Diamond 2/20/2006 2/22/2006 Comments 1 No comments made 1 Plans are not consistant with regard to fire hydrant locations. 2 Fire hydrants and FDC shall be located a minimum of 1 1/2 times the height of the building away from the building 3 Indicate fire lane radii on site plan 4 Fire hydrant and FDC for Bldg 4 needs to be relocated to an area away from Bldg 5 5 Headache bar over fire lane shall have a minimum of 14' clearance No comments SITE PLAN 1 Show fire lanes, mutual access and utility easements on the Site Plan, do not need to indicate actual utility lines on this plan 2. The PD approved two monument sign for Tract 2, one on SH 121 and 1 on Forest Hills Drive, four monument signs are being shown Need to comply with the PD in terms of number, location and size of signs. 3 Correct typo in Notes ~nrl r.nnditions (thoroughfare) 4 Will the four dumpters adjacent to building 4 serve all three buildings? 5 This needs to be titled Lot2R, Block A of the Vista Point II addition 6 The building setback line along SH 121 needs to be 60 feet, and 30' setback is permitted adjacent to internal lot lines Setback lines need to be consistent between the site plan and the plat. LANDSCAPE PLAN 1 A PD condition waives the requirement for perimeter landscaped buffers between interior lot lines, and allows for the landscaping requirements to be calculated on the overall acreage of the PO as opposed to a tract-by-tract basis. When the original PD was approved, there was 7,953 square feet of overage of landscaped area for the entire development (Tracts 1-7) Update the Landscape Summary for the entire PD(including the site plan for Tract 5 - Bank of Texas) THE CITY o F COPPELL ...~- * .~. ~ ;-~-" X J'\ .s \ ~ Agency Reviewed By THE C I T Y o F CITY OF COPPELL ORC REPORT COPPELL ...~. . ~ " l' .t '" .s l ~ q Review Date Comments to insure that the landscape requirements are still being met. ELEVATIONS Sheet A3 01 1 Remove the "project name" from the height restriction bar, signage (except for the 10'-6" Maximum Clearance) will not be permitted. 2. Remove the random 28% next to the Material Percentage box. 3 Complete the sheet, replacing the XX's with correct numbers or delete. 4 Need to verify the size of the monument signs, whereas the base is counted as part of the area of the sign, it appears that the 40 square foot sign is actually 42.5 square feet and the 60 square foot sign is actually 63 75 square feet. Sheet A3 02 1 Indicate what the dashed square on the rear elevation is for - future windows, doors, overhead doors? 2. Complete the sheet, replacing the XX's with correct numbers or delete. Sheet A3 03 1 Building Five Southwest Elevation - per the PD Ordinance, side elevations are required to be a minimum of 25-30% masonry, correct the data box to indicate 29%(?) masonry Sheet A3 04 1 Indicate what the dashed square on the rear elevation is for - future windows, doors, overhead doors? 2. Complete the sheet, replacing the XX's with correct numbers or delete Sheet A3 05 1 Building Four Southwest Elevation - per the PD Ordinance, front elevations are require to be a minimum of 35-40% masonry, only 32% masonry is indicted, revise elevations as required. 2. Complete the sheet, replacing the XX's with correct numbers or delete THE CITY o F THE C I T Y o F COPPELL COPPELL ..~~* .. ~ Q e q ..t .." 5 \ Y, CITY OF COPPELL ORC REPORT Proiect ID Address RP-06-0010 609 State Highway 121 Proiect Tvoe Aoolication Date Case Manaaer Project Descriotion Replat 2/15/2006 Proiect Name Vista Point Ii, Lot 2R. Block A, Replat Marcie Diamond to revise the locations of the fire lanes to allow the development of three buildings containing a total of approximately 115,525-square feet on 10 046 acres of property Agency Building Inspection Electric and Gas Engineering Fire Administration Parks and Recreation Planning Department Reviewed By Greg Jones 1 of 1 Review Date 2/20/2006 Tim Oates John Elias Marcie Diamond 2/23/2006 2/20/2006 2/22/2006 Comments 1 No platting comments made on Replat. No comment regarding the Replat No comments. 1 Review all details, including the alignments of the fire lane/mutual access easements as established by Vista Point II, Final Plat (Cab V, Page 952), AND the Amending Plat of Vista Point II, (Cab W, page 598) to assure that all easements are correctly designated and labeled 2. Change the scale of the plat to match the scale of the site plan 3 It appears that there has been an adjustment to the alignment of the Fire Lane and Mutual Access Easement as it intersects with Lot 1 4 This property is in Denton County - so references to the existing filed plat are "Cab" instead of "Volume" 5 Add the distance to all the building lines (i e 60' Building Line) 6 The name of this plat needs to be Lot 2R, Block A, Vista Point II, (Business Center is not part of the official name of the plat) -revise all references 7 Designate the width of all fire lane and mutual access easements (24') 8 Building line along SH 121 is 60 feet.