Loading...
Northlake 635(7)-CS060223DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM. • Northlake 635 Business Park. Lot 2. Block B. (PSINet. Lot 1. Block A). Site Plan Amendment to allow a two -story 17,550 - square -foot expansion to the existing Crestside Facilities building on 6.527 acres of property located at 1333 Crestside Drive, at the request of Bill Homrighausen, Constructors & Associates. STAFF REP.: Matt Steer PROJECT ID# SPR -06 -0011 DRC DATE: March 2, 2006 7 Kenneth M. Griffin. RE.. Dir.ofEnnineerinwPublic Works 9721304 -3686 COMMENT STATUS: I ✓PRELIMINARY Construction plans should be submitted for review and construction permit should be applied for through the Engineering Department. Additional comments may be generated upon detailed engineering review. T H E C 1 T Y O F COPPELL Project ID Address SPR -06 -0011 1333 Crestside Dr Project Type Application Date Case Manager Project Description Site Plan Amendment (Revision) 2/15/2006 Matt Steer CITY OF COPPELL DRC REPORT Proiect Name T H E C 1 T Y O F COPPELL r o Northlake 635 Business Park,lot 2, Block B(psinet to allow a two -story 17,550- square -foot expansion to the existing Crestside Facilities building on 6.527 acres of property Agency Reviewed By Building Inspection Greg Jones Electric and Gas Engineering Fire Administration Tim Oates Parks and Recreation John Elias Planning Department Matt Steer 1 of 1 Review Date Comments 2/22/2006 1 With Floor Plans not being furnished, it is difficult to determine whether exit path and means of egress is being properly maintained with this expansion project. Need further info at permit stage. 2/23/2006 No comment at this time. 2/20/2006 No comments. 2/23/2006 Site Plan 1 Show existing bollards on site plan 2. The floor area ratio appears too high 3 Provide maximum number of employees on any one shift. 4 Change title on all plans to read - Northlake 635 Business Park Lot 2, Block B (PSI Net Addition Lot 1, Block 1) Crestside Facilities. 5 Label the storage area as one -story and the office area as two -story 6 The area labeled "no visible striped parking" might be better suited as a "future parking area" Landscape Plan 1 Show dimensions of property 2 Ensure all landscape area calculations (Perimeter, nonvehicular, interior) are stand alone and not overlapping (being counted more than once). 3 Nonvehicular landscape area is calculated as the total 15% of the (site area - building area) 4 Show existing bollards and shrubs on plans 5 Ensure trees within the TXU Easement are acceptable to TXU Elevations 1 Continue cast stone star accents on proposed south elevations. 2. Submit a color board with rendering and materials at the DRC meeting