Loading...
Lost Creek TH-CS060223DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM.• PD-213-H. Coooell Commons, zoning change request from H (Historic) to PD- 213-H (Planned Development-213-Historic) with a Concept Site Plan to allow the development of 39 townhouse units, recreation, open space and common areas on 5.561 acres of property located along the east side of Coppell Road, approximately 210 feet north of Bethel Road, at the request of Mardy Brown, Dowdey, Anderson & Associates, Inc. STAFF REP.: Gary Sieb PROJECT ID# PD-06-0007 DRC DATE: March 2, 2006 CONTACT.• Kenneth M. Gri en, P.E., Dino En ineerin ublic Works 972/304-3686 COMMENT STATUS: /PRELIMINARY ~#A~ ~E-~€i3 ~~ Preliminary Engineering 1. Show off site development that has taken place adjacent to the property on this sheet. 2. Provide an 8" stub off of the Mobley Way water line that extends to the east property line. The stub should be within an easement and located in "Open Space". The City will connect the stub to an existing water line on Anderson Avenue. 3. The storm sewer line proposed to empty to the creek should instead be tied to the stub that exists in the variable width utility easement along the east side of the site. 4. The portion of the sanitary sewer line that does not lie within the ROW should be within a minimum 20' utility easement. 5. Sidewalks that do not lie within the ROW should be located within side walk easements. 6. Provide utility easements in the locations where ROW is reduced due to HOA parking spaces. The easements should cover the difference in standard ROW width. 7. Provide a typical utility and driveway layout for the 26' lot width. The proposed 26' may be objectionable if not adequate. 8. Although none is proposed, please note that no construction will be allowed in the 100- year flood plain. 9. Easements meeting the City's minimum standards will need to be provided during the platting process. 10. The water line shown to connect to the sewer line should be corrected. 11. Is the parallel parking necessary? 12. Consider placing a wheel stops in the parking spaces at the Pommers Ct. cul-de-sac. This may help minimize potential damage to fencing along the abutting property lines. Exhibit "A" 1. 6.0 Road, Alley and Parking Regulations, #5: Minimum parking space width is Nine (9) feet. 2. 6.0 Road, Alley and Parking Regulations, #7: Lay down curbs will only be allowed with the approval of the City Engineer. An additional one foot of street width will be required for each side of the street that the use of lay down curb is allowed. 3. 7.0 Building Regulations, #1: Modify to read "Residential units shall not front on Coppell Road." Additional comments may be generated upon detailed engineering review. T M e c l r r o F COPPELL ~ ~ T O F 9 x ,~ s 1 s ProiectlD PD-O6-0007 Address 560 Coppell Rd CITY OF COPPELL DRC REPORT Proiect Name T N ! C 1 T Y O F COPPELL ~ ~ T p F x n a I g q PD-213-H, Coppell Commons Proiect Tvge Re-Zoning PD Aoglication Date 2/15/2006 Case Manager Gary Sieb Proiect Description zoning change request from H (Historic) to PD-213-H (Planned Development-213-Historic) with a Concept Site Plan to allow the development of 39 townhouse units, recreation, open space and common areas on 5.561 acres of property 1 of 2 Agency Reviewed By Review Date Comments Building Inspection Greg Jones 2/20/2006 1 No comments made on project. Electric and Gas Engineering Fire Administration Tim Oates 2/23/2006 1 Townhomes shall be protected by automatic fire sprinkler systems. 100% coverage in accordance with CFD policy 2. Provide water line lay-out indicating size of pipe and location of fire hydrants. Parks and Recreation John Elias 2/20/2006 1 Tree Survey is incomplete. Based on information shown $6,600.00 will be required in Tree Retribution and a Tree Removal Permit will be required prior to construction starting 2. Park Development Fees (39 x $1285 = $50,115 00) T H E C 1 T Y O F T H ! G 1 T Y O F COPPELL CITY OF COPPELL COPPELL ~T `~ ~€ ~ ,o ~ DRC REPORT ~r ~ ~ ~~ ,,~ e X A s D q F X ^ 5 t g 4 Agency Reviewed By Review Date Comments Planning Department Gary Sieb 2/22/2006 SITE PLAN 1 Dimension all parking spaces 2. Chandos Lane should be Mobley Way 3 Change name of Pommers Court. 4 Proposed use is PD-H (TH-2) 5 Density should not exceed 6.5 DU's per acre 6 Uses adjacent to Coppell Road do not conform to Old Coppell Master Plan 7 All street row should be 50 feet. 8 Show zoning on all adjacent land areas 9 No more than 6 du's in a row 10 Maximum building height should not exceed 35 feet. 11 Parking spaces on apron do not count for any parking credit, remove note 12. Remove note stating 4.5 parking spaces per dwelling unit, 2.5 spaces required/unit. 13 Minimum lot depth should be at least 100 feet 14 Maximum building height is 35 feet. ELEVATIONS EXHIBIT 1 Dimension room sizes 2. Need front, side, and rear elevations 3 Indicate all building materials used in structures proposed 4 Color Board is required 5 Indicate different floor plans as "A", "B", " C" or similar notation and indicate on Site Plan LANDSCAPE PLAN 1 Maximum distance between wall columns is 30 feet 2. Need color board of wall building materials. 3 How are common areas maintained? irrigated?, HOA? DEVELOPMENT STANDARDS, EXHIBIT "A" 1 Zoning would be PD-H (TH-2) Z. Minimum lot depth should be 100 feet. 3 Buildings should have a minimum 15 foot separation 4 Maximum building height is 35 feet. 5 Need copy of HOA document. 6 Maximum density shall not exceed 6.5 du's per acre 7 Specify caliper of trees to be planted. 8. Street trees shall have a caliper of at least 3 inches. 9 Sidewalks shall meet the same dimension as existing walks to the north. 10 Parking shall be provided at no less than 2.5 units per dwelling unit. 11 Apron parking spaces are not counted in Coppell, modify condition 12 Lay down curbs are not allowed in this subdivision, modify condition 13 Facade offsets should be at least 5-8 feet.