Loading...
Amberpoint BP 2R-LR060512CONCRETE COMPRESSIVE STRENGTH TEST Report Number 94051418 0382 Service Date• May 3, 2006 l~~rr~con 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date. May 12, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No • 94051418 Material Information Specified Strength 3600 psi @ 28 Days Batch Time 8 59am Plant: 2 Supplier Potter Truck No 109 Ticket No 101620 Mix I D No 7752 Water Added Onsite Before Test. OGallons Water Added Onsite After Test. 0 Gallons Field Test Data Test Slump, inches Air Content, Concrete Temperature, of Ambient Temperature,oF Plastic Unit Weight, pcf~ Result 5 50 35 85 82 Sample Information Date Cast. May 3, 2006 Time 8 40am Sampled by Mario A. Garcia Weather Conditions: Partly cloudy Accumulative Yards: 20/40 Placement Method Direct Discharge Sample Locations 10' N & 3' W of S corner of approach Placement Location Approach off Freeport Pkwy at NW corner of job site Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 * =Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq, inches) Tested days) (Ibs) (psi) 1 1 6 00 28.27 05/10/2006 7 110,580 3,910 1 2 6 00 28 27 05/10/2006 7 100,760 3,560 Average (7 Days) 3,740 1 3 05/31 /2006 28 1 4 05/31/2006 28 Comments. Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep Mario A. Garcia Report Distribution (1} Transwestern Commercial Services (1) TechniStructures (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by• (1) City of Coppell TX Hussein H Abusaad, P.E. (1) O'Brien 8 Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of f o+-~S~RO+-F~,~ Kai