Loading...
Amberpoint BP 2R-LR060511REPORT OF REINFORCING STEEL OBSERVATION l~+~rr~Can Consulting Engineers & Scientists 8902 Carpenter Fray Suite p100 Dallas, Texaz 75247 (2141630-1010 Date of Service OS/11/06 Client No S08S4 y~.~~-n--'"' Client Transwestern Co~merclal Services 5001 Apr-tng Valley Rd Ste 600 W Dallas, TX 75244 ~~., Services Observe placement of reinforcing for compliance with furnlshe PROJECT DATA Drawings Utilized CI O1 and A2 1, dated 02/03/06 and 04/1S/OS Report No 94051418 0392 Project No Project 94051418 AmberPomt Business Park Buildings 4, 5 and 6 SOS South Royal Lane Cc Locations/Items Observed NW Entrance, Fire Lane and Pavement on the NW corner of Job Site off of Northpomt Dnve Test Method Visual Observation ~~~ REPORT OF OBSERVATION OD~ ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBS CORRECT INCORRECT Placing Dravnngs Approved X Bar Lenglh and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance ~' DiscrepancieslComments Any discrepancies found were corrected at the time of this observation unless otherwise noted ~l~ Field Results Report To Technician E Jernlgari Report Distribution (1) Transwestern Commercial Services (1) Rogers O'Brien Construction Co (1) City of Coppell TX (1} O'Brien & Assoc ___],~~ ~ (1} City of Coppe(I TX (1) TechniStructures ~~!~j/~~(~`/ Hussein H. Abusaad, P.E Senior Project Manager 309acs This report is exclusively for the use of the cBenl indicated above and shaft not be reproduced without written approval of Terracon. CONCRETE COMPRESSIVE STRENGTH TEST Report Number 94051418 0354 11~rracon 8901 Carpenter Frwy, Ste #100 Service Date April 12, 2006 Dallas, Texas 75247 (214) 630-1010 Client: Report Date: May 11, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No 94051418 Material Information Specified Strength 3600 psi @ 28 Days Batch Time 5 52am Plant. 2 Supplier Potter Concrete Truck No 107 Ticket No 101241 Mix I D No 7752 Water Added Onsite Before Test. 0 Gallons Water Added Onsite After Test. 0 Gallons Field Test Data Test Result Slump, inches 4 50 Air Content, % 5 1 Concrete Temperature, of 68 Ambient Temperature,~F 65 Plastic Unit Weight, pcf~ 140 7 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6 00 28.27 Sample Information Date Cast: April 12, 2006 Time 6 10am Sampled by• Sammy D Roberts Weather Conditions. Partly cloudy Accumulative Yards: 30 Placement Method Direct Discharge Sample Locations. 30' N & 520' W Placement Location Pavement, Building #4 from NE back corner between Building #4 and Building #5 Specification 3-5 3-6 Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (tbs) (psi) 04/19/2006 7 123,630 4,370 1 2 6 00 28.27 04/19/2006 7 124,990 4,420 Average (7 Days) 4,400 1 3 6 00 28.27 05/10/2006 28 153,570 5,430 1 4 6 00 28.27 05/10/2006 28 161,400 5,710 Average (28 Days) 5,570 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use' of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location{s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 Of 5 oi-aowam-F~n~.a KaY CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418 0354 l~err~con Service Date April 12, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214)630-t010 Client: Report Date May 11, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No : 94051418 Material Information Specified Strength 3600 psi @ 28 Days Batch Time 7 34am Plant: 2 Supplier Potter Concrete Truck No 109 Ticket No 101256 Mix I D No 7752 Water Added Onsite Before Test. OGallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches 5 00 Air Content, % 4 8 Concrete Temperature, ~F 7p Ambient Temperature,~F 65 Plastic Unit Weight, pcf• 141 9 Laboratory Test Data Set Specimen Diameter Area No ID (inches) (sq inches) 2 1 6 00 28.27 2 2 2 3 2 4 6 00 28.27 6 00 28.27 6 00 28.27 Samale Information Date Cast. April 12, 2006 Time 7 45am Sampled by• Sammy D Roberts Weather Conditions: Clear Accumulative Yards. 180/ Placement Method Direct Discharge Sample Locations 100' N & 500' W Placement Location Pavement, Building #4 from NE back corner between Building #4 and Building #5 Specification 3-5 3-6 Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) ((bs) (psi) 04/19/2006 7 96,280 3,400 04/19/2006 7 98,200 3,470 Average (7 Days) 3,440 05/10/2006 28 128,860 4,560 05/10/2006 28 130,470 4,610 Average (28 Days) 4,590 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 o+-aowROaFUw,xay CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051418 0354 Service Date: Aril 12, 2006 8901 Carpenter Frwy, Ste #100 P Dallas, Texas 75247 (214) 630-1010 Client: Report Date: May 11, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.: 94051418 Material Information Specified Strength 3600 psi @ 28 Days Batch Time 9 15am Plant 2 Supplier Potter Concrete Truck No 106 Ticket No 101271 Mix I D No 7752 Water Added Onsite Before Test. 0 Gallons Water Added Onsite After Test. 0 Gallons Sample Information Date Cast. April 12, 2006 Time 9.30am Sampled by' Sammy D Roberts Weather Conditions: Clear Accumulative Yards. 350/ Placement Method Direct Discharge Sample Locations• 60' N & 400' W Placement Location Pavement, Building #4 from NE back corner between Building #4 and Building #5 l~~rracon Field Test Data Test Result Slump, inches 4 50 Air Content, % 5 3 Concrete Temperature, of 71 Ambient Temperature,~F 67 Plastic Unit Weight, pcf• 142.3 Specification 3-5 3-6 Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 ASTM C138 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6 00 28.27 3 2 6 00 28.27 3 3 6 00 28.27 3 4 6 00 28.27 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 04/19/2006 7 91,790 3,250 04/19/2006 7 94,180 3,330 Average (7 Days) 3,290 05/10/2006 28 118,430 4,190 05/10/2006 28 119,710 4,230 Average (28 Days) 4,210 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 01-PDR1R01-FUlure Key CONCRETE COMPRESSIVE STRENGTH TEST Re ort Number 94051418 0354 l~~rr~con p Service Date: April 12, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date• May 11, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.: 94051418 Material Information Sample Information Specified Strength 3600 psi @ 28 Days Date Cast. April 12, 2006 Time 11 OOam Sampled by' Sammy D Roberts Batch Time 10 37am Plant: 2 Weather Conditions Clear Supplier Potter Concrete Accumulative Yards 440/ Truck No 107 Ticket No 101282 Placement Method Direct Discharge Mix I D No 7752 Sample Locations 100' N & 280' W Water Added Onsite Before Test. OGallons Placement Location Pavement, Building #4 from NE back corner Water Added Onsite After Test. 0 Gallons between Building #4 and Building #5 Field Test Data Test Result Specification Test Method Slump, inches 5 00 3-5 ASTM C-143 Air Content, % 5 3 3-6 ASTM C-231 Concrete Temperature, ~F 73 ASTM C-1064 Ambient Temperature,~F 68 ASTM C-1064 Plastic Unit Weight, pcf~ 141 8 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No ID (inches) (sq. inches) Tested (days) (Ibs) (psi) 4 1 6 00 28 27 04/19/2006 7 81,510 2,880 4 2 6 DO 28 27 04/19/2006 7 85,790 3,030 Average (7 Days) 2,960 4 3 6 00 28.27 05/10/2006 28 110,040 3,890 4 4 6 00 28.27 05/10/2006 28 116,130 4,110 Average (28 Days) 4,000 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 °'-'°"'R°'_F~`e "aY CONCRETE COMPRESSIVE STRENGTH TEST R rt Number 94051418 0354 Sample Information Date Cast. April 12, 2006 Time 1.25pm Sampled by' Sammy D Roberts Weather Conditions. Accumulative Yards. 620/ Placement Method Direct Discharge Sample Locations 75' N & 200' W Placement Location Pavement, Building #4 from NE back corner between Building #4 and Building #5 epo Service Date Aril 12, 2006 8901 Carpenter Frwy, Ste #100 p Dallas, Texas 75247 (214) 630-1010 Client: Report Date: May 11, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.• 94051418 Material Information Specified Strength 3600 psi @ 28 Days Batch Time 1 04pm Plant: 2 Supplier Potter Concrete Truck No 101 Ticket No 101300 Mix I D No 7752 Water Added Onsite Before Test. 0 Gallons Water Added Onsite After Test. 0 Gallons Field Test Data Test Slump, inches Air Content, Concrete Temperature, °F Ambient Temperature,°F Plastic Unit Weight, pcf~ Result 4 50 50 76 70 141 7 Laboratory Tesf Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 5 1 6 00 28.27 5 2 6 00 28.27 5 3 6 00 28.27 Specification 3-5 3-6 l~err~con Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 04/19/2006 7 85,640 3,030 04/19/2006 7 72,410 2,560 Average (7 Days) 2,800 05/10/2006 28 107,460 3,800 5 4 6 00 28.27 OS/10/2006 28 109,020 3,860 Average (28 Days) 3,830 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples Terracon Rep Sammy D Roberts Report Distribution (1) Transwestern Commercial Services (1) TechniStructures '~"~ (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by' (1) City of Coppell TX Hussein H. Abusaad, P.E. (1) O'Brien ~ Assoc Senior Project Manager The tests were pertormed in general accordance with applicable ASTM, AA5HT0, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 °'-`°R"'°,-F~,a"eY