Loading...
Freeport NIP(8.1)-LR060309Rone Engineering Project: Services: Page 1 of 2 Client: Duke Construction LP Mr Bruce Barclay 5495 Belt Line Rd Ste 360 Dallas TX 75254 Freeport XIV XV 800 700 W Bethel Road Coppell, Texas Reinforcing Steel inspection On this date, a Rone Engineering Services, Ltd representative(s) arrived on site as scheduled to perform Reinforcing Steel Inspection The results are attached Technician Time Technician: Jimmy Hall Report Distribution: (1) Duke Construction LP (1) Extranet (I) Pond, Robinson Associates 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, SIc 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 REPORT OF REINFORCING STEEL INSPECTION 12.00am 2:15am Report of Inspection Report No.: Project No.: Date of Service: Report Date: 251859 0510795 03/01/2006 03/09/2006 K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc or any other feature of similar subject matter provided by persons or conditions over which we have no control Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd 99 TM Items Inspected: Conforming Non Lontommng Items Inspected: Conforming Non uontormrag Items Inspected: Conforming Non r,7ontormmg Placing Drawings Approved x Bar Length and Shape x Column ties Properly Tied and Spaced NA Bar Size x Proper Bar Placement x Stirrup Spacing NA Bar Grade x Properly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Proper Bar Supports x Comer Bars NA Number of Bars x Proper Cover x Mechanical Splices NA Rone Engineering Client: Duke Construction LP Project: Freeport XIV XV Date of Service: 3/1/2006 Page 2 of 2 Locations and Itelns Inspected Northeast side of Building 14, paving (180'). Discrepancies Comments: Report of Reinforcing Steel Inspection Report No.. 251859 Project No 0510795 1. No chairs and dowel covers. Discrepancies noted above to be corrected prior to concrete placement. Inspector's Signature. Client/Contractor Signature Client/Contractor Copies with Results Yes No 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort worth, TX 76118 7701 W Little York, Suite 600, Itouston 77040 Corporate Phone: (214) 630 -9745 LIMITATIONS. The test results presnrled herein we1e prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appr_+rancs, performance, etc.) or any other texture of 5lrtaLlf subject made: provided by persons or conditions over which we have no control Utu levers end reports we for ome exclusive use of the clients to whom they are addressed and shall not be reproduced except m lull w1llxwl the wnhvi approval 01 hone bl5aneettng Services. Lid.