Amberpoint BP 2R-LR060519CONCRETE COMPRESSIVE STRENGTH TEST l~~rr~cor~ Report Number 94051418 0391 Service Date May 11, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date- May 19, 2006 Transwestern Commercial Services Project. AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No . 94051418 Material Information Specified Strength 4600 psi @ 28 Days Batch Time 6 54am Plant. 2 Supplier Potter Truck No 104 Ticket No 101707 Mix I D No 7723 Water Added Onsite Before Test. OGallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Sample Information Date Cast: May 11, 2006 Time 7 30 a m Sampled by' Eric G Jernigan Weather Conditions Partly sunny, cool Accumulative Yards 20/150 Placement Method Pump Sample Locations Fire Lane at NW corner of job Placement Location 5" Pavement of NW corner of job NW Entrance, Fire Lane and Pavement Specification 3-5 3-5 Test Method Slump, inches Air Content, Concrete Temperature, ~F Ambient Temperature,~F Plastic Unit Weight, pcf~ Laboratory Tesf Data 5 00 3.2 80 65 Set Specimen Diameter Area No. ID (inches) (sq inches) 1 1 6 00 28 27 2 6 00 28 27 3 4 ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 05/18/2006 7 133,720 4,730 05/18/2006 7 123,460 4,370 Average (7 Days) 4,550 06/08/2006 28 06/08/2006 28 Comments' Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples Terracon Rep Eric G Jernigan Report Distribution (1) Transwestern Commercial Services (1) TechniStructures J (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by~ ~/ (1) City of Coppell TX ° (1) O'Brien & Assoc Hussein H Abusaad, P E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 Of 1 of ncsraei Fu~,a keY CONCRETE COMPRESSIVE STRENGTH TEST N b 94051418 0393 1 ~~rracon Report um er Service Date Ma 11, 2006 8901 Carpenter Fnvy, Ste #100 Y Dallas, Texas 75247 (214} 630-1010 Client: Report Date May 19, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No. 94051418 Material Information Specified Strength 3600 psi @ 28 Days Batch Time 9 32am Plant. 2 Supplier Potter Concrete Truck No 104 Ticket No 101722 Mix I D No 7752 Water Added Onsite Before Test 0 Gallons Water Added Onsite After Test. 0 Gallons Field Test Data Test Slump, inches Air Content, Concrete Temperature, °F Ambient Temperature,°F Plastic Unit Weight, pcf• Result 4 00 36 87 72 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6 00 28.27 Sample Information Date Cast. May 11, 2006 Time 9 55am Sampled by Eric G Jernigan Weather Conditions Sunny, clear, mild Accumulative Yards 20/110 Placement Method Pump Sample Locations Center of Approach Placement Location Pavement, Fire Lane and Parking on NW corner of job site Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) {psi) 05/18/2006 7 128,650 4,550 1 2 6 00 28.27 05/18/2006 7 116,490 4,120 Average (7 Days) 4,340 1 3 06/08/2006 28 1 4 06/08/2006 28 Comments Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples Terracon Rep Eric G Jernigan Report Distribution (1) Transwestern Commercial Services (1) TechniStructures (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by• (1) City of Coppell TX Hussein H Abusaad, P E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1 °'.""R°'"`°`"ekav