Northlake 635(7)-CS060518CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE: Northlake 635 Business Park, Lot 2, Block B, (PSINet, Lot 1, Block A) P & Z HEARING DATE C C HEARING DATE STAFF REP LOCATION SIZE OF AREA CURRENT ZONING May 18, 2006 June 13, 2006 Matt Steer. City Planner 1333 Crestside Drive 6 527 acres of property LI (Light Industrial) REQUEST To relocate the fire lane to accommodate the two - story, 27,200- square -foot addition (13,600- square feet per floor) to the existing Crestside Facilities building on 6 527 acres of property located at 1333 Crestside Drive APPLICANT Architect Merriman Associates Brian Degravelle 300 N Field St. Dallas, TX 75202 Phone (214) 987 -1299 Fax (214) 987 -2138 En ineer O'Donald Engineering Brandon O'Donald 8912 Sirocka Dr Benbrook, TX 76116 (817) 560 -5480 (817) 560 -1618 Contact Contractors & Associates Bill Homrighausen 3333 Welborn St, 4200 Dallas, TX 75219 (214) 525 -5114 (214) 520 -0413 HISTORY On Julv 14, 1998, Council approved a Site Plan and Minor Plat on this property to allow for the construction of an 80,000 - square -foot office building At that time, the proposed user for the property was a call center Item # 5 Page 1 of 3 Although the building was constructed and the site fully developed and landscaped, it was never occupied for that use On March 14, 2000, Council approved a Replat and an Amended Site Plan for this building to allow for the construction of a 20,120- square -foot courtyard area addition to house mechanical equipment to serve a start-up internet access provider, PSINet Unfortunately they occupied this building for less than a year In August 2003, a Minor Amending Site Plan, supported by the Fire Marshal, was administratively approved to allow for the closing of one driveway and the widening of another, with a gated entrance and additional landscaping In November 2003, Council approved an amendment allowing for a sunbrella fabric canopy to cover 28 parking spaces In October 2005, another Minor Amending Site Plan was administratively approved for the addition of bollards and shrubs along the perimeter of the site On March 16, 2006, a site plan amendment to allow a two -story, 17,550 - square -foot expansion to the existing structure was recommended for approval by the Planning and Zoning Commission. Subsequent to the meeting, the applicant requested that the item be removed from the City Council agenda in order to increase the proposed expansion to 27,200 square feet. TRANSPORTATION Lakeshore Drive is a concrete street with a 41 -foot pavement width within a 60 -foot right -of -way Crestside Drive is a concrete street with a 37 -foot pavement width within a 60 -foot right -of -way. SURROUNDING LAND USE & ZONING North - Office LI (Light Industrial) South - vacant, A (Agriculture) East - warehousing, LI (Light Industrial) West - warehousing, LI (Light Industrial) COMPREHENSIVE PLAN The Comprehensive Plan shows the property as suitable for Light Industrial /Showroom uses DISCUSSION The purpose of this Replat is to relocate the fire lane easement on the south side of the existing structure to allow for the proposed 27,200 - square -foot two -story expansion Item # 5 Page 2 of 3 RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION Staff is recommending APPROVAL of this request. subject to the following conditions 1) Remove the notary signature block located below the City Secretary signature block 2) Comply with the attached Engineering comment sheet. ALTERNATIVES 1) Recommend approval of the request 2) Recommend disapproval of the request 3) Recommend modification of the request 4) Take under advisement for reconsideration at a later date ATTACHMENTS 1) Replat 2) Engineering comment sheet Item # 5 Page 3 of 3 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE: Northlake 635 Business Park, Lot 2R, Block B, Site Plan Amendment (PSINet, Lot 1, Block A) P & Z HEARING DATE May 18, 2006 CC HEARING DATE June 11, 2006 STAFF REP Matt Steer, City Planner LOCATION 1333 Crestside Drive SIZE OF AREA 6 527 acres of property CURRENT ZONING LI (Light Industrial) REQUEST To allow a two -story, 27,200- square -foot addition (13,600- square feet per floor) to the existing Crestside Facilities building on 6 527 acres of property located at 1333 Crestside Drive APPLICANT Architect Merriman Associates Brian Degravelle 300 N Field St. Dallas, TX 75202 Phone (214)987 -1299 Fax (214) 987 -2138 Engineer O Donald Engineering Brandon O'Donald 8912 Sirocka Dr Benbrook, TX 76116 (817) 560 -5480 (817) 560 -1618 Contact Contractors & Associates Bill Homrighausen 3333 Welborn St, #200 Dallas, TX 75219 (214) 525 -5114 (214) 520 -0413 HISTORY On July 14, 1998, Council approved a Site Plan and Minor Plat on this property to allow for the construction of an 80,000- square -foot office building At that time, the proposed user for the property was a call center Item # 4 Page 1 of 3 Although the building was constructed and the site fully developed and landscaped, it was never occupied for that use On March 14, 2000, Council approved a Replat and an Amended Site Plan for this building to allow for the construction of a 20,120- square -foot courtyard area addition to house mechanical equipment to serve a start-up internet access provider, PSfNet. Unfortunately, they occupied this building for less than a year In August 2003, a Minor Amending Site Plan, supported by the Fire Marshal, was administratively approved to allow for the closing of one driveway and the widening of another, with a gated entrance and additional landscaping In November 2003, Council approved an amendment allowing for a sunbrella fabric canopy to cover 28 parking spaces. In October 2005, another Minor Amending Site Plan was administratively approved for the addition of bollards and shrubs along the perimeter of the site On March 16, 2006, a site plan amendment to allow a two - story, 17,550 - square -foot expansion to the existing structure was recommended for approval by the Planning and Zoning Commission. Subsequent to the meeting, the applicant requested that the item be removed from the City Council agenda in order to increase the proposed expansion to 27,200 square feet. TRANSPORTATION Lakeshore Drive is a concrete street with a 41 -foot pavement width within a 60 -foot right -of -way Crestside Drive is a concrete street with a 37 -foot pavement width within a 60 -foot right -of -way SURROUNDING LAND USE & ZONING North - Office, LI (Light Industrial) South - vacant, A (Agriculture) East - warehousing, LI (Light Industriai) West - warehousing, LI (Light Industrial) COMPREHENSIVE PLAN The Comprehensive Plan shows the property as suitable for Light Industrial /Showroom uses DISCUSSION This request is for a new two -story office addition to the south side of the existing structure The addition is extending into an area previously used as parking and fire lane, therefore, the parking space total is being reduced from 267 to 216 and the fire lane is being shifted south. The reduction in Item # 4 Page 2 of 3 parking will not bring the site out of conformance with our parking regulations The uses are now being classified as 33,900- square feet of computer area and 63,652- square feet office area, bringing the required parking to 210 spaces The proposed elevations will match the existing structure, the majority being a reddish -brown "Park Rose" with a band of dark brown "Ironstone" with cast stone star accents and windows throughout There are a total of 28 new trees being added to the site Twelve Redbud ornamentals are being added within the 13 -foot TP &L easement on the south property line The remaining trees are over -story and have been added throughout the site to meet the tree requirements of the Landscape section of the Zoning Ordinance All and all, staff is in support of the building addition, the fire lane shift and landscaping modification and has only minor changes to be made (listed as conditions of approval) RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION Staff is recommending APPROVAL of this request, subject to the following conditions 1) The new addition shall be designed using brick with steel framework adjacent to fire lane, so that any potential wall failure during fire conditions will minimize chance of failure into collapse zone 2) A tree removal permit will be required prior to start of construction. 3) Contact Jeff Curry at 972- 888 -1330 to discuss electric load requirements 4) Remove bold line on the southwest section of the site and show all existing bollards 5) The floor area ratio should read 377 to 1 6) Verify all required /provided tree calculations for each landscaping category (Perimeter, Non - vehicular and Interior) AL 1 ERNA I INLS 1) Recommend approval of the request 2) Recommend disapproval of the request 3) Recommend modification of the request 4) Take under advisement for reconsideration at a later date ATTACHMENTS 1) Site Plan 2) Landscape Plan 3) Elevations Item # 4 Page 3 of 3 T H E C 1 T Y O F COPPELL T o Proiect ID Address S PR -06 -0016 1333 Crestside Dr Project Type Application Date Case Manager Proiect Description Agency Building Inspection Electric and Gas Engineering Fire Administration Site Plan Amendment (Revision) 4/20/2006 Matt Steer CITY OF COPPELL DRC REPORT Project Name T H E C 1 T Y O F COPPELL T Northlake 635 Business Park, Lot 2, Block B to allow a two story 27,200 square -foot addition (13,600 square feet per floor) to the existing Crestside Facilities building Parks and Recreation Planning Department 1 of 1 Reviewed By Review Date Comments Greg Jones 4/25/2006 1 Previously, there has been some concern with the new two story construction being so close to the Fire Lane that structural failure during fire conditions could cause building collapse into the Fire Lane Coordinate building structural systems with Fire /Building Inspection departments to minimize this hazard Jeff Curry 4/27/2006 No Comments Received Charlene La Mattina 4/27/2006 No Comments Tim Oates 4/27/2006 1 Fire hydrants on south side of property shall be on building side of 6ft screening wall John Elias 4/25/2006 1 Need to know the size of all existing trees to determine tree mitigation 2 Tree removal permit is required prior to start of construction Matt Steer 4/27/2006 Site Plan 1 Rename Site Plan to "Site Plan Amendment Northlake 635 Business Park Lot 2R, Bock B, (PSINet Lot 1, Block A) 2 Check number of parking spaces provided 3 Remove notes that indicate there's an existing 6' high pre -cast concrete screen wall 1 Dimension pr cposcd parking spaces 5 Indicate what is proposed vs what is existing 6 Expand landscape island at the end of a parking row where not utilized for parking 7 Explain how loading area functions Landscape Plan /Tree Survey - 1 Review existing and proposed landscaping calculations (three categories of landscaping - perimeter, interior, non - vehicular) See attached sheet for a breakdown of how calculations are determined Each category is stand alone, and cannot be included within another 2 Expand landscape island at the end of a parking row where not utilized for parking 3 Include required chart as part of tree survey Elevations 1 Indicate window type on black and white elevations T H E C 1 T Y O F COPPELL T O Project ID Address RP -06 -0018 1333 Crestside Dr Project Type Application Date Case Manaoer Project Description Agency Building Inspection Electric and Gas Engineering Replat 4/20/2006 Matt Steer CITY OF COPPELL DRC REPORT Project Name T H E C 1 T Y O F COPPELL Northlake 635 Business Park, Lot 2, Block B To relocate the fire lane to accommodate the two -story, 27,200- square -foot addition (13,600- square feet per floor) to the existing Crestside Facilities building Fire Administration Parks and Recreation Planning Department 1 of 1 Reviewed By Review Date Comments Greg Jones 4/25/2006 1 No plating comments Jeff Curry 4/27/2006 No Comments Received Charlene La Mattina 4/27/2006 1 Water lines 10" in diameter and smaller shall be Class 200, DR -14 Please modify the utility notes accordingly 2 Construction plans should be submitted for review and construction permit should be applied for through the Engineering Department. Additional comments may be generated upon detailed engineering review Tim Oates 4/27/2006 No comments regarding the replat. John Elias 4/25/2006 No comments Matt Steer 4/27/2006 1 Rename plat to "Replat Northlake 635 Business Park Lot 2R, Block B, (PSI Net, Lot 1, Block A) 2 Correct all signature blocks (Owner's Dedication and Surveyor's Certificate) 3 Add City Secretary, Mayor, Planning and Zoning Commission Chairperson, Mayor, Flood Plain Administrator, and Utility Companies (Atmos Energy, TXU Electric Delivery, Verizon and Comcast) Signature Blocks. 4 Ensure all existing easements are shown (Previous plat shows and underywund electric easement not shown) 5 Change information within the drawing to show Lot 1, Block A, PSINet Addition faded with the new title above it. T H E C I T Y O F COPPELL E I � Agency Planning Department T H E C 1 T Y O F CITY OF COPPELL COPPELL DRC REPORT y J 9 0 I 9 Reviewed By Review Date Comments Marcie Diamond 4/26/2006 Plat: 1 Correct the title block on both sheets to Lots 1 R1 and 1R2 2 Make new property line between the two lots thicker, it's hard to locate and /or provide a detail to illustrate how the new property line, and new private utility easement overlap the existing fire lane and water easements 3 Correct the vicinity map on both sheets to reflect Freeport Parkway, instead of State Road 4 Remove the Volume and Page box and notations (blank lines) on both sheets, Dallas County is using an new filing /recording system. 5 Correct the Owner's Certificate (metes and bounds description) to describe this property, instead of a property in the Freeport-Duke Addition 6 Correct the Lot numbers to Lots 1 R1 and 1 R2 in the Owner's Dedication and the City Secretary's Signature block. 7 Page 2, Notes Correct the basis for the bearing system used for this plat. 8 Verify the square footage of each lot, as they do not total the square footage of the original lot, or the two lots added together Landscape Plan As previously stated, after replatted, Lot 1 R2 needs to be in compliance with all provisions of the Landscape Ordinance, because Lot 1 R1 (the Citi financial lot) has been placed under a PD to address the parking and landscape issues This PD is scheduled (again) to be heard on May 9th LOT 1 R2 (the southern lot) 1 Need to indicate new lot line on Lot 1 R2, and verify the number of location of trees on the respective lots, indicating the required 10 feet of perimeter landscaping on each side of the lot, and revise perimeter calculations accordingly 2. Need to verify that the existing trees, shrubs and landscaped areas are as was proposed in the approved landscape plan 3 Comparing the landscape calculations from the approved (1997) landscape plan for Lot 1R2 and the revised calculations submitted with this request: How did the size of the parking area increase by 58,952 square feet? There are also inconsistencies with the lot areas exclusive of building, whereas, the approved landscape plan indicates 386,190 scl ft., revised plan 381,711 sq ft. and as calculated, utilizing the replatted lot area (678,541), minus the approved building area (297,902) equals 380,639 square feet. Once the area figures are corrected, please adjust all applicable landscape calculations