Denton Tap 3A-LR060531 (2)CLIENT Head Construction, Inc
3030 LBJ, Ste 700
Dallas, TX 75234
STANDARD 6" X 12"
AREA 28.27 SQ. IN
REPORT DATE 5/31/06
PROJECT. Proposed Copp Montessori Academy
136 Fitness Ct.
SAMPLE DATE:5 /31/06
Coppell, TX
PROJECT NO. 817TXIK5
ATTN. Ken Head
REPORT NO 9
SE&T TECHNICIAN Justin Speaks
LOCATION OF PLACEMENT Sidewalk S Of Bld• Sta 1
+62
PAGE 1 OF 1
Time Arrived 7 00 AM
Concrete Supplier
TX'
Time Left: 8 00 AM
Ticket 262585
Slump (Inches) 4 5
Truck 82
Concrete Temperature (F) 64
Time Batched 6 16 AM
Air Content: N/A
Time Sampled 7 10 AM
Total No of Test Cylinders Made 4
Product Code 8272
Total Cubic Yards Placed 10
Cement: N/A
Added Water N/A
Fly Ash N/A
Weather Conditions Cool
Coarse Aggregate N/A
Air Temperature (F) 70
Water N/A
Unit Weight of Fresh Concrete 148
Air Content N/A
Specimen
a
Unit
Iota! Lo
Co p s[vre 3
s Length tin
lidrt ilb
C
Lb
Strength l p5
race
i
1A
7
6/7/06
3000/28
1B
14
6/14/06
3000/28
1C
28
6/28/06
30007
1D
28
6/28/06
wf ;r
3000/28
Curing ASTM C -31
Test Method
Cy(nd ade /gy
Cylinders Tested By
Slump ASTM C -143
ASTM C -39 231
E&T
::YYourS
y
7 e'
Sadi k (SAM) Al-Musawe, M Sc Ph D
P E d O
p
Civil Environmental Engineer
Texas Registration Number 61893
This report is for the sole use of the client addressed The use of our company name must receive our prior written consent
This report only applies to the samples tested and does not necessarily represent identical or similar samples
SAM ENGINEERING TESTING, L.P.
Serving The Geo- Industry Since 1974
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone (972) 790 -1910 FAX. (972) 790 -0967
Materials
Testing
Geotechnical
Environmental
CONCRETE PLACEMENT INSPECTION STRENGTH TEST REPORT
Failure