Loading...
Denton Tap 3A-LR060531 (2)CLIENT Head Construction, Inc 3030 LBJ, Ste 700 Dallas, TX 75234 STANDARD 6" X 12" AREA 28.27 SQ. IN REPORT DATE 5/31/06 PROJECT. Proposed Copp Montessori Academy 136 Fitness Ct. SAMPLE DATE:5 /31/06 Coppell, TX PROJECT NO. 817TXIK5 ATTN. Ken Head REPORT NO 9 SE&T TECHNICIAN Justin Speaks LOCATION OF PLACEMENT Sidewalk S Of Bld• Sta 1 +62 PAGE 1 OF 1 Time Arrived 7 00 AM Concrete Supplier TX' Time Left: 8 00 AM Ticket 262585 Slump (Inches) 4 5 Truck 82 Concrete Temperature (F) 64 Time Batched 6 16 AM Air Content: N/A Time Sampled 7 10 AM Total No of Test Cylinders Made 4 Product Code 8272 Total Cubic Yards Placed 10 Cement: N/A Added Water N/A Fly Ash N/A Weather Conditions Cool Coarse Aggregate N/A Air Temperature (F) 70 Water N/A Unit Weight of Fresh Concrete 148 Air Content N/A Specimen a Unit Iota! Lo Co p s[vre 3 s Length tin lidrt ilb C Lb Strength l p5 race i 1A 7 6/7/06 3000/28 1B 14 6/14/06 3000/28 1C 28 6/28/06 30007 1D 28 6/28/06 wf ;r 3000/28 Curing ASTM C -31 Test Method Cy(nd ade /gy Cylinders Tested By Slump ASTM C -143 ASTM C -39 231 E&T ::YYourS y 7 e' Sadi k (SAM) Al-Musawe, M Sc Ph D P E d O p Civil Environmental Engineer Texas Registration Number 61893 This report is for the sole use of the client addressed The use of our company name must receive our prior written consent This report only applies to the samples tested and does not necessarily represent identical or similar samples SAM ENGINEERING TESTING, L.P. Serving The Geo- Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone (972) 790 -1910 FAX. (972) 790 -0967 Materials Testing Geotechnical Environmental CONCRETE PLACEMENT INSPECTION STRENGTH TEST REPORT Failure Investigation