Connell Skaggs-CS 870323
-. .
11
i~
'l
GINN, INC.
CONSULTING ENGINEERS
TO:
Shohre Daneshmand, Civil Engineer
Attn: Taryon Bowman, Senior Planning Technician
Ginn, Inc.
March 23, 1987
Final Plat/Site Plan; Lots 1, 2, and 3
Connell Skaggs Addition
NW Corner Denton Tap Road./Sandy Lake Road
FROM:
DATE:
SUBJECT:
After reviewing the above referenced project, we offer the
following comments:
Our last review and comments on this property were made in April
1986, and then again in July 1986. Since that time, we have not
been a part of the review process on this particular subject.
Therefore, some of our comments mayor may-not be applicable due
to prior discussions, agreements, or provisions made by and
between the owners, engineers, and city staff.
1. We requested previously that dedication of right-of-way
along Denton Tap be provided to have 140' wide right-of-way
within 300 feet of intersection. Also, Denton Tap right-of-
way needs to be 120' wide in accordance with County requests.
2. Prior concerns over drainage on west end of property are
still valid at this point in time.
3. We have major concerns about entire site "sheet" flowing to
west into the drainage ditch; no provision for on-site
detention or collection.
4. Storm drainage should use 100-year storm, not 50-year as shown.
5. When "sheet flow" hits screening wall on west property line,
what will happen?
6. Screening wall should be a part of initial site development,
not future.
7. The City does not recommend clay tile pipe for sewer mains;
would prefer PVC.
8. No open cutting of Denton Tap or Sandy Lake shall be allowed
for water or sewer improvements.
9. Will the 6" thick concrete pavement be adequate for truck
traffic.
10. Please include latest revised detail sheets as part of plans.
GaIJe ~
Gabe Favre
17103 Preston Road. Suite 100 . LB 118 . Dallas, Texas 75248 . Phone 214/248-4900