Loading...
Gateway BP(1.6)-CS060614;;; Halff Associates 8616 Northwest Plaza Drive Dallas, Texas 75225-4292 (214)346-6200 Fax (214) 739-0095 LETTER OF TRANSMITTAL TO: Charlene La Mattina, E.I T DATE• June 14, 2006 City of Coppell Engineering Dept. 255 Parkway Blvd. AVO: 23906 Coppell, TX 75019 PROJECT: Gateway Business Park Lot 3B, Block 2 FROM• Ben Stephens, E.I T bstephens ~ halff.com VIA: WE ARE SENDING YOU ® Attached: ^ Under separate cover ^ Shop Drawings ^ Prints ® Plans ^ Drawings ^ Specifications ^ Copy of letter ^ Change order ^ Submittals ^ Other• THESE ARE TRANSMITTED as checked below: ® For approval ^ Approval as submitted ^ For your use ^ Approved as noted ® As requested ^ Returned for corrections ^ For review/comment ^ Other• ITEMS SENT: 2 full-size sets of revised Construction Plans Engineering Dept. review set of original submittal Review comment reply memo and exhibit Letter requesting variance from City's lime stabilization requirement COMMENTS: ^ Resubmit copies for approval ^ Submit copies for distribution ^ Return corrected prints Please contact myself at 214-217-6684 or bstephensC~halff com or Pat Acker at 214-346-6240 or packer@halff.com with any questions or comments SIGNED• Ben Stephens, E.I T PREPARED BY COPIES. ® File ^ Owner ^ Contractor ^ Other• ~c.v (_ 1 ~ ~ t--t ~S ~ ~ I•\23000s\23906\Correspondence\LOT060614_Coppell-Engineering Plan Resubmittal doc ;;e Halff Associates MEMORANDUM TO: Charlene La Mattina, E.I T DATE: City of Coppell Engineering Dept. AVO: FROM: Ben Stephens, E.I T Email bstephensC~3halff.com PROJECT: SUBJECT. Reply to Construction Plan Review Comments 8616 Northwest Plaza Drive Dallas, Texas 75225-4292 (214) 346-6200 Fax (214) 739-0095 June 14, 2006 23906 Gateway Business Park Lot 3B, Block 2 All of the comments were addressed by revising the plans, except for comments 5 and 15 (see below) Notes on particular comments. 3. Areas A-1, A-3, and A-6 were reduced to 0.59, 0.25, and 0 42 cfs draining into the streets, respectively (A-1 was divided, with A-1 now draining to an additional inlet and A-8 draining into the street) This is the minimum amount of flow we could achieve and still grade from the street to the parking areas at acceptable grades. 5. Modifications to the existing median nose will not be required, based on a turning radius for a WB-50 truck. Attached is a print-out showing the turning radius layout at this location At minimum there is over 5 feet of clearance to the face of curb of the median nose from the inside of the truck turning area. 8. Attached is a letter of request for variance from the lime stabilization requirement, prepared by Reed Engineering Group 14 The profile view of the proposed bore was added to a new sheet C4 02. 15 The proposed location of the south DDC vault will not interfere with the existing 10-inch sanitary sewer line A typical vault size from manufacturer's catalogs is 11 feet by 7 feet outside dimensions. Our sheets currently show the vaults as 12 by 8, which still allows about 6' clearance to the outside of the sanitary sewer line. 17 The sanitary sewer line was lowered 6 inches The proposed water line bottom of pipe is now just over 2.5 feet above the proposed sanitary sewer top of pipe, based on our proposed grading, which meets the TCEQ requirement of 2' clearance required to avoid encasement. A profile of the sanitary sewer is included in sheet C4 02 with a note showing a minimum 2' clearance in the case that the final grading is a few inches off from the plan contours. 19 The curb inlet was replaced with a grate inlet and the grading was revised so that the area of B-7 within the right-of-way flows to the grate inlet, while the private commercial drive still drains to the inlet along the drive I.123000s123906\Correspondence\Memo060614_Coppell-Engineering Plan Resubmittal.doc Turning Radius for WB-50 Truci:, 120' Turn l (Per TxDOT Roadway Design Manual) Outside Radius per Fig.7-3 {Pg.7-17) Inside Radius per Fig. 7-7 {Pg. 7-21), Table 7-2 (Pg. 7-2~ for 3-Centered Asymmetric Compound Curve