Amberpoint BP 2R-LR060608FIELD DENSITY TESTING • 94051418 0425 lf~rracon Report Number. 8901 Carpenter Frwy, Ste#100 Service Date May 31, 2006 Dallas, Texas 75247 (214) 630-1010 Client: Report Date: June 08, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.: 94051418 Material Information Material Laboratory No Test Method escription and Classification Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight (%) (pcf) Proiect Requirements Water Minimum Dry Content Unit Weight {%) (°~6 compaction) 1 514180003 ASTM D 698 Reddish brown sandy clay 14 8 112.3 >/_ +3 93 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Wei ht No Test Location Elev No (inches) (%) (pcf) (°~ co action) Slab Leaveout 662 2' N & 20' W of SE corner 2' BFG 1 6 17 9 106.2 95 663 2' N & 60' W of SE corner 2' BFG 1 6 18 5 106 0 94 664 2' N & 100' W of SE corner 2' BFG 1 6 18 7 105 9 94 665 2' N & 130' W of SE corner 2' BFG 1 6 18 1 105 7 94 Datum BFG =below final grade Comments. Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition Field Test Method ASTM D-2922, ASTM D-3017 Terracon Rep Armando Rendon Field Results Reported To Superintendent Report Distribution (1) Transwestern Commercial Services (1) TechniStructures (1) City of Coppell TX (1) Rogers O'Brien Construction C° Reviewed by' (1) City of Coppell TX Hussein H. Abusaad, P.E. (1) O'Brien 8 Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 07-PDR/R07-FUIiAB Key FIELD DENSITY TESTING b 94051418 0422 l~~rracon Report Num er. 8901 CarpenterFrwy, ste#1oo Service Date• May 30, 2006 Dallas, Texas 75247 (214)630-1010 Client: Report Date: Ju _- Transwestern Commercial Services Project: AmberP ss ark - - ~,.~.~ Attn David Gunderson _ -- Ings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.. 94051418 Lab Test Data Proiect Requirements Material Information Optimum Max. Lab Water Dry Unit Water Minimum Dry Material Laboratory Content Weight Content Unit Weight No Test Method Description and Classification (%) (pcfl (%) (°~ compaction) 1 514180001 ASTM D 698 Brown clay w/sand 19 0 101.2 >/_ +3 93 Field Test Data Test No Test Location Building 4 660 300' W of SE corner of Building 661 200' W of SE corner of Building Datum. BFG =below final grade Comments Probe Lift/ Mat. Depth Elev No (inches) 1' BFG 1 8 1' BFG 1 8 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) {% compaction) 180 * 961 95 13 0 * 97 0 96 An asterisk (") appears next to test results which do NOT meet the project specifi ns. Services - Perform in-place density and moisture content tests to determine de of compaction and material moisture condition Field Test Method ASTM D-2922, ASTM D-3017 9/ ~`l~ Terracon Rep Burl E. Thomas Field Results Reported To Mr Harper Report Distribution ~.i~~~°~ (1) Transwestern Commercial Services (1) TechniStructures ~C~~~f'~`~ f (1) City of Coppell Tx {1) Rogers O'Brien Construction Co Reviewed by fll~' (1) City of Coppell TX Husse n H. Abusaad, P.E. (1) O'Brien & Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o~voamol-FN~~a ker FIELD DENSITY TESTING Report Number: 94051418 0432 Service Date: June 2, 2006 11~rr~con 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date: June 08, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.: 94051418 Material Information Material Laboratory No Test Method 1 514180003 ASTM D 698 Field Test Data Test No Lab Test Data Proiect Requirements Optimum Max. Lab Water Dry Unit Water Minimum Dry Content Weight Content Unit Weight Description and Classification (%) (pcf) (%) (°,6 compaction) Reddish brown sandy clay 14 8 112.3 >/_ +3 93 Probe Water Dry Unit Dry Unit Lift/ Mat. Depth Content Weight Weight Test Location Elev No (inches) (%) (pct) (% com~ctic Slab Leaveout 671 Retest of Test #669, dated 6/1/06 1 6 18 1 106 4 95 672 Retest of Test #670, dated 6/1 /06 1 6 18 4 106 8 95 673 2' S & 120' W of NE corner 1' BFG 1 6 18 6 106 0 94 Datum: BFG =below final grade Comments Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition Field Test Method ASTM D-2922, ASTM D-3017 Terracon Rep Armando Rendon Field Results Reported To Contractor Report Distribution (1) Transwestern Commercial Services (1) TechniStructures (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by• (1) City of Coppell TX (1) O'Brien 8 Assoc Hussein H Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 W-0DR/RO]-FVUre Hey FIELD DENSITY TESTING R rt N ber• 94051418 0437 l~~rracon epo um 8901 Carpenter Frwy, Ste #100 Service Date: June 5, 2006 Dallas, Texas 75247 (214) 630-1010 Client: Report Date: June 08, 2006 Transwestern Commercial Services Project: AmberPoint Business Park Attn David Gunderson Buildings 4, 5 and 6 5001 Spring Valley Rd Ste 600 W 505 South Royal Lane Dallas TX 75244 Coppell, TX Project No.: 94051418 Material Information Material Laboratory No Test Method 1 514180003 ASTM D 698 2 514180003 ASTM D 698 Field Test Data Test Description and Classification Reddish brown sandy clay Reddish brown sandy clay No Test Location Probe Lift/ Mat. Depth Elev No (inches) Lab Test Data Project Requirements Optimum Max. Lab Water Dry Unit Water Minimum Dry Content Weight Content Unit Weight (%) (pefl (%) (% compaction) 14 8 112 3 >/_ +3 93 14 8 112.3 >/_ +3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pct) (% compactio Slab Leaveout 674 2' S & 20' W of NE corner Final 2 6 18 6 110 5 98 675 2' S & 80' W of NE corner Final 2 6 18 9 109 8 98 676 2' N & 80' E of SW corner 2' BFG 1 6 17 8 106 4 95 677 2' N & 120' E of SW corner 2' BFG 1 6 18.2 106 5 95 678 2' N & 150' E of SW corner 2' BFG 1 6 18 0 105 9 ' 94 Datum: BFG =below final grade Comments Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition Field Test Method ASTM D-2922, ASTM D-3017 Terracon Rep Armando Rendon Field Results Reported To Contractor Report Distribution (1) Transwestern Commercial Services (1) TechniStructures (1) City of Coppell TX (1) Rogers O'Brien Construction Co Reviewed by' (1) city of Coppell TX Hussein H. Abusaad, P.E. (1) O'Brien 8 Assoc Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o,_,IX„~o,-F~,a kaY