Loading...
St Joseph-LR060626CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051415.0007 Service Date: June 14, 2006 Irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: St Joseph Village Inc Attn: Joseph Dingman 13223 Glad Acres Dr Dallas TX 75234 Report Date: June 26, 2006 r ,,,�•�''""'" Project: St. J lapel 01 East Sandy Lake Rd. Coppell, TX Pro ject N o.: 94051415 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 7:29 AM Plant: 01 Supplier: Nelson Bros. Ready Mix Truck No: N/A Ticket No: 167117 Mix I.D. No.: PD33 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 0.4 Concrete Temperature, aF: 56 Ambient Temperature,OF: 66 Plastic Unit Weight, pcf: 148.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 2 6.00 28.27 3 4 Sample Information Date Cast: June 14, 2006 Time: 8:22 AM Sampled by: Joseph P. Martinez Weather Conditions: Clear, sunny Accumulative Yards: 7/7 Placement Method: Direct Discharge Sample Locations: S side Sidewalk, 10' S & 8'W of SE corner of Chapel Placement Location: Sidewalks on N, S & W sides of Chapel Specification 3 -5 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days (lbs) (psi) 06/21/2006 7 65,890 2,330 06/21/2006 7 66,120 2,340 Average (7 Days) 2,340 07/12/2006 28 07/12/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Joseph P. Martinez Report Distribution: (1) St Joseph Village Inc (1) Lobsinger & Potts (1) City of Coppell TX (1) Parma Design Reviewed by: (1) City of Coppell TX (1) Haglar Construction A. Bulent Ethem, P.G. (1) Charter Assoc Inc Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is ex c usively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 oi- PDRRoi - F M Key