Loading...
Denton Tap 3A-LR060628SAM ENGINEERING TESTING, L.P. It Serving The Geo- Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790 -1910 FAX: (972) 790 -0967 Materials Testing CONCRETE PLACEMENT INSPECTION STRENGTH TEST REPORT Geotechnical Environmental r•nnntict 7fvileAlrnicirlr micf ran I Failure Investigation CLIENT: PROJECT: ATTN: Time Arrived: Head Construction, Inc 3030 LBJ, Ste: 700 Dallas, TX 75234 Proposed Coppell Montessori Academy 136 Fitness Ct. Coppell, TX Ken He SEAT TECHNICIAN: Justin Speaks LOCATION OF PLACEMENT: Sidewalk S. Of BId 7:00 AM STANDARD 6" X 12" AREA 28.27 SQ. IN. Sta 1 +62 PAGE 1 OF 1 REPORT DATE:6 /28/06 SAMPLE DATE: 5/31/06 PROJECT NO.: 817TXIK5 REPORT NO.: 9 Concrete Supplier: TXI Time Left: 8:00 AM Slump (Inches): 4.5 Concrete Temperature (F): 64 Air Content: N/A Total No. of Test Cylinders Made: 4 Total Cubic Yards Placed: 10 Added Water N/A Weather Conditions: Cool Air Temperature (F): 70 Unit Wei ht of Fresh Concrete: 1A 7 6/7/06 148 147 89,000 Cylinders Tested By: SE &T 1B 14 1C 28 1D 28 6/14/06 6/28/06 6/28/06 Curing ASTM C -31 Slump ASTM C -143 147 108,000 149 111,000 149 117,000 Test Method ASTM C -39 231 Ticket 262585 Truck 82 Time Batched: 6:16 AM Time Sampled: 7:10 AM Product Code: 8272 Cement: N/A Fly Ash: N/A Coarse Aggregate: N/A Water: N/A Air Content 3147 N/A ngle Shear 3000/28 392 le Shear 3000/28 3819 le Shear 3000/28 4 gle Shear 3000/28 Remarks: Tested concrete meets /exceeds required strength. Very Truly Yours, Sadik (SAM) Al- Musawe, M.Sc., Ph.D Civil Environmental Engineer Texas Registration Number: 61893 P.E. ks This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples. Of CLIENT: Head Construction, Inc 3030 LBJ, Ste: 700 Dallas, TX 75234 PROJECT: Proposed Coppell Montessori Academy 136 Fitness Ct. Coppell, TX ATTN: Ken Head STANDARD 6" X 12" AREA 28.27 SQ. IN. REPORT DATE: 6/28/06 SAMPLE DATE:5 /30/06 PROJECT NO.: 817TXIK5 REPORT NO.: 8 SE&T TECHNICIAN: Adel Alhemidawi LOCATION OF PLACEMENT: East Side of Fire Lane A• •roach PAGE 1 OF 1 Time Arrived: 7:30 AM Concrete Supplier: TXI Time Left: 8:20 AM Ticket 861953 Slump (Inches): 5 Truck 82 Concrete Temperature (F): 84 Time Batched: 6:53 AM Air Content: N/A Time Sampled: 7:50 AM Total No. of Test Cylinders Made: 4 Product Code: 8274 Total Cubic Yards Placed: 50 Cement: N/A Added Water: 15 Gallons Fly Ash: N/A Weather Conditions: Partly Cloudy Mild Coarse Aggregate: N/A Air Temperature (F): 80 Water: N/A Unit Wei ht of Fresh Concrete: 145 Air Content k' N J N/A P $6' F q x 1A A 7 6/6/06 144 82,000 m 2900 Single Shear 3600/28 1B 14 6/13/06 144 92,000 3253 Single Shear 3600/28 1C 28 6/27/06 146 114,000 4031 Single Shear 3600/28 1D 28 6/27/06 146 116,000 4102 Single Shear 3600/28 Curing ASTM C -31 Test Method Cylinder Made By: Cylinders Tested By: Slump ASTM C -143 ASTM C -39 231 SE&T SE&T Remarks: Tested concrete meets /exceeds required strength. Very Truly Yours, Sadik (SAM) Al- Musawe, M.Sc., Ph.D., P.E. Civil Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report only applies to the samples tested and does not necessarily represent identical or similar samples. SAM ENGINEERING TESTING, L.P. Serving The Geo- Industry Since 1974 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790 -1910 FAX: (972) 790 -0967 CONCRETE PLACEMENT INSPECTION STRENGTH TEST REPORT Geotechnical Materials Failure Testing Investigation Environmental