Loading...
TR0301-LR060810 LAWRENCE ENGINEERING ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder SUite B Dallas Texas 75243 Phone (972) 497-9100 Fax (972) 497-9108 CLIENT PROJECT LE REPORT #. REPORT DATE CONCRETE INSPECTION AND COMPRESSION TEST REPORT City of Coppel! REPORT DISTRIBUTION Traffic Signal Improvements Rick O'Del! - City of Coppell C06-0707-04 8/10106 Strength (pSI) Slump (in) Air Content (%) Concrete Temp (OF) SPECIFICATIONS 4000 @ 28 days 3-5 3-6 95 max PROJECT DATA Placement Date 7/13/2006 Sampled By A. Maya Weather Sunny Supplier/Mix LMc 11701 Ticket # Slump (in) Conc Temp (OF) Placement Location Remarks FIELD DATA SET #1 3217125 Time Batched 1230 PM Time Sampled 5 0 ,A.lr Content: 4 2 Unit Weight: 92 Ambient Temp (OF) 94 Yardage (c y ) One (1) Light pole foundation - SW corner of MacArthur Blvd & Bethel Sch Rd 1 25 PM N/A 10 Ticket #. Slump I in I Conc Temp \ OF) Placement Location Remarks FIELD DATA SET# Time Batched Air Content: Ambient Temp (OF) Time Sampled Unit Weight: Yardage (c y ) CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39 Set # Cylinder # T est Date Age (Days) Max Load (Ibs) Area (sq in) Strength (psi) FC Notes 1-1 7/20/2006 7 112500 2827 3980 A 1 1-2 7/20/2006 7 109440 2827 3870 A 1-3 8/10/2006 28 140640 2827 4970 D 1-4 8/10/2006 28 136220 2827 4820 D 11) NORMAL CYLINDER SIZE 6" X 12" ARE,A 2827 sq In UNLESS NOTED ABOVE 12) FAILURE TYPE A=CONE B=CONE AND SPLIT C=CONE AND SHEAR 0=SHEAR E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SP:::CIFICATIONS UNLESS INDICATED IN NOTES 14) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS C138 C143 C172 C231 L:\ProJectslPrOjects 2006\C06-0707 Traffic SignallmprovementsIC06-D707-04 Concrete Insp Report 7-13 xis